Zystm hinges etc - Flipbook - Page 15
Order no.
Appendix
Page
Initials
891928-1
2
1 of 1
jju/jha/hbs
Testing of Model: Hinge
The cabinet was fastened against tilting by means of clamps. The door was then opened 90° and loaded
100 mm from the edge of the handle. The permanent deflection was measured vertically from the lower
edge of the door and down to the floor. The loading was increased gradually. Neither door nor hinges
show signs of breakage.
Requirement in BS 5873 part 4:1998, section 5.2.1 level, hard is 45 kg.
Loading
kg
0
25
35
45
55
65
75
85
95
Deflection, loaded
mm
122
122
121
121
121
120
120
119
119
Permanent deflection
mm
122
122
122
122
122
121
121
121
121
105
115
119
119
125
135
119
118
121
121
121
145
155
118
118
165
175
118
118
185
195
117
117
205
117
121
121
121
121
121
121
121
121
15