Zystm hinges etc - Flipbook - Page 12
Report no.
Appendix
Page
Initials
891928-1
1
4 of 4
jju/jha/hbs
Testing of Model: Hinge/Cabinet
6. Strength and Durability
Table 5 – Strength and Durability Tests
Test
no.
Test
Strength of clothes rail supports
Reference
EN 16122:2012
6.3.1
6.1.1
6.1.2
6.1.3
6.1.4
6.1.5
6.1.6
6.1.7
6.1.8
Strength of coat hooks
9.1
Durability of pivoted doors
Slam shut test of pivoted doors
7.1.5
7.1.4
Slam shut/open of sliding doors
and horizontal roll fronts
Durability of sliding doors and
horizontal roll fronts
7.2.2
Durability of flaps
Durability of vertical roll fronts
Durability of extension elements
7.3.2
7.4.2
7.5.3
7.2.3
6.1.9
Slam shut and open of extension
elements a
7.5.4
6.1.10
7.5.5
6.1.14
6.1.15
Displacement of extension element bottoms
Strength test for locking and
latching mechanisms for extension elements
Strength test for locking and
latching mechanisms for doors,
flaps and roll fronts
Drop test
Deflection of shelves
6.1.16
Dislodgement of clothes rails
6.3.2
6.1.17
Drop test for trays
8.3
6.1.18
6.2
Sustained load test for trays
Strength and durability requirements
a) There are no fractures of any
member, joint or component
b) There are no loosening of
joints intended to be rigid
c) The storage unit fulfils the stability requirements (5.6)
d) The storage unit fulfils its
functions after removal of the
test loads
e) There shall be no deflection of
shelves that exceeds 0.5% of
the span of the shelf when
tested in accordance with test
no. 6.1.15 (see Table 5)
8.2
6.1.11
6.1.12
6.1.13
7.6.2
7.6.3
6.4.2
6.1.4
Loading
Mass per unit
length, kg/dm
Time
Force per hook, N
Cycles
Cycles
Mass, m2, kg
Cycles
Mass, m2, kg
Cycles
Cycles – sliding
doors
Cycles – roll
fronts
Cycles
Cycles
Cycles – extension elements
Cycles – trays
Velocity, m/s, at
calibration points
Slam open 5 kg
Slam shut 35 kg
Factor K
Force, N
Cycles
Force, N
Cycles
Force, N
Cycles
Drop height, mm
Mass per unit
area, kg/dm2
Mass per unit
length, kg/dm
Drop height, mm
Cycles
Kg/dm3
Test severity
1
2
4.0
1h
4.0
1h
40
10
40.000
3
10
4
10
150
10
80.000
4
10
6
10
20.000
10.000
40.000
20.000
N/A
10.000
10.000
20.000
20.000
N/A
N/A
40.000
20.000
80.000
40.000
N/A
1.30
1.00
2.5
1.30
1.00
2.5
N/A
60
10
70
10
N/A
200
10
200
10
N/A
200
10
200
10
N/A
-
50
N/A
1.5
2.0
Passed
5
5
N/A
350
10
0.65
700
10
1.0
a
For strength and durability tests, only the slam shut test shall be performed. Table 4 contains requirements for slam open test
N/A Not applicable
12
Result
N/A
N/A
Passed
Passed
N/A
N/A
N/A
Passed
Passed
Passed
Passed
Passed