Testing of Model: Hinge/Cabinet
5.6 Stability
The requirements for stability only apply to units, where the height to the top of the unit is 650 mm or
more above the floor level, and when the potential energy, exceeds the value 65.
Where specified, the unit shall be loaded in accordance with the loads specified in Table 2. When the unit
or component is conspicuously and durably marked by the manufacturer with a maximum load, the unit
or component shall be loaded with the stated maximum load multiplied by 0.5, but the load shall not exceed the value calculated using Table 2.
Table 3 – Stability Tests
Test
no.
5.6.1
5.6.2
5.6.3
5.6.4
5.6.5
5.6.6
5.6.7
Test
Doors, extension elements and
flaps closed, all storage units unloaded – units that are, or can be,
adjusted to a height of 1000 mm
or less
Doors, extension elements and
flaps closed, all storage units unloaded – units that are, or can be,
adjusted to a height of more than
1000 mm
All storage areas unloaded and all
doors, extension elements and
flaps open
All storage areas unloaded with
overturning load
All storage areas loaded with overturning load
Doors, extension elements and
flaps closed and locked
Dynamic stability test for units
with castors a
Reference
EN 16122:2012
Loading
Requirement
Result
11.2.1
Vertical force, N
750
N/A
11.2.2
Vertical force, N
Outward force, N
350
50
Passed
11.4.1
-
-
Passed
11.4.2
Vertical force, N
100
Passed
11.4.3
Vertical force, N
20% of total
mass (3.5)
of the unit
but not
greater than
300 N
N/A
11.5
Outward force, N
100
N/A
11.6
-
-
N/A
a
The test shall be carried out in accordance with EN 16122:2012, 11.6 except that the stops shall be 12 mm high with square edges
N/A Not applicable