Saniflo Designer Hub - Catalog - Page 50
INSTALLATION GUIDE
10 golden rules for correct installation
Detailed installation instructions accompany every product. Please provide access for any
service requirements.
1
2
PVC
Ball Value
1:100
All horizontal pipes should have a minimum fall of 1:100.
Discharge pipework should be uPVC. Do not use ‘pushfit’
pipework/fittings.
3
2 x 45 Offset
Plastic Elbows
Bends should be smooth/long radius, not tight elbows.
Examples of uPVC pressure pipe and fittings shown.
5
Increase pipe size
from here
Where the pipework falls below floor level increase the
pipe size to break siphonage.
7
Easily
removable
panels
The unit should be easily accessible and removable in the
event of service or maintenance being required. If boxed
in, the boxing should be easily removed. Any extension
between the WC pan spigot and wall should not exceed
200 mm and have a 1.40 fall.
9
Position the Saniflo unit directly behind the toilet pan,
not underneath it.
If a vertical rise is needed, this should be at the start of
the run (within 30 cm of the unit) and from the high point
there must be a minimum fall of 1:100 (see Rule 1).
4
1:40 grade
or 3%
Waste pipes entering the Saniflo unit should have
a gravity fall of 1:40 or 3%.
6
Each Saniflo discharge pipe should run separately to the
sewer/vent pipe. If wastes are combined, it can only be
to a larger pipe, which is on a gravity fall.
8
As close coupled cistern dimensions vary it may
be necessary with certain designs to use a spacer
between cistern and wall.
10
ELECTRICAL CLASS 1 PRODUCT
Connect to power according AS 3000 Electrical
Regulation as rules apply depending on location.
For technical support in AUS: 1300 554 779 or technical@saniflo.com.au
For technical support in NZ: 0800107264 or technical@saniflo.co.nz