Stelrad Vita Series July 2024 - Flipbook - Page 31
CAST IRON COLUMN
50
(75/65/20ºC)
4 COLUMN
Height
mm
Length
mm
Sections
660
760
Stelrad
UIN
Heat output
Watts
Btu/h
Weight
(kg)
512
8
264001
744
2539
44
573
9
264002
837
2856
50
634
10
264003
930
3173
56
695
11
264004
1023
3490
61
756
12
264005
1116
3808
67
816
13
264006
1209
4125
72
877
14
264007
1302
4442
78
938
15
264008
1395
4760
83
999
16
264009
1488
5077
89
1060
17
264010
1581
5394
94
1120
18
264011
1674
5712
100
1181
19
264012
1767
6029
106
512
8
264013
864
2948
50
573
9
264014
972
3316
56
643
10
264015
1080
3685
62
695
11
264016
1188
4053
68
756
12
264017
1296
4422
75
816
13
264018
1404
4790
81
877
14
264019
1512
5159
87
938
15
264020
1620
5527
93
t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20ºC. If you have a low temperature
heat source you may wish to consider t40 or t30 output (see your installer or system designer or download from www.stelrad.com).
Due to production tolerances, the length of the product and therefore the tap centres could contain a variation of +/- 1.5% of the overall stated length.
For EN442 data, technical and installation information please visit our website: www.stelrad.com and search product downloads.
For systems not operating at DeltaT 50 the correction factors table on page 76 should be applied.
ONLY AVAILABLE IN A NATURAL CAST FINISH.
DELIVERY INFORMATION:
Please note: Due to the weight of the product a 2-man lift is required and there is a £90 incl. VAT shipping charge per order, per destination for
orders under £1800 incl. VAT.
The delivery driver is only able to stop at the closest point on the road at the nearest accessible external hard standing, i.e. pavement.
Due to health and safety legislation the driver is prohibited from lifting any heavy goods (25kg = max. single person lift). They are not insured to enter
the property. It is your responsibility to organise the manpower thereafter to be available to move your radiators to a suitable and dry storage area.
Cast Iron Column radiators are delivered individually wrapped with each individual radiator layer separated with a thick card then secured flat
onto the pallet(s).
Cast Iron Column radiators have up to a 14 day lead time.
OPTIONAL VALVES
263060
Antique Brass
263061
Brushed Nickel
The thermostatic radiator valve comes with an in-built temperature sensor which maintains the room at the temperature you have selected.
6
BAR
WORKING
PRESSURE
AUGMENTED
REALITY APP
AVAILABLE
Natural
cast
31