Rointe Heating Catalogue 2023 UK-IE - Catalog - Page 94
ACCESSORIES
INSTALLATION KITS
ROINTE
VENICE INSTALLATION KIT
It’s mandatory for unvented domestic hot water heaters to be installed with an installation kit. This kit is compatible
with Venice 10/15 L water heaters.
Installation scheme A
Installation scheme C
When inlet pressure is less than bar and expanded hot water
can be put in pipework.
When inlet pressure is greater than 4 bar.
4
2
2
1
1
6
Cold water suppy
Cold water suppy
Hot water outlet
3
Cold water inlet
Hot water outlet
3
5
Cold water inlet
To drain
To drain
Length “X”
INSTALLATION DETAILS
Installation scheme B
When inlet pressure is less than 4 bar but expanded hot water
cannot be put in pipework.
4
2
1
Cold water suppy
Hot water outlet
5
Cold water inlet
1
2
3
4
5
6
Expansion relief valve (included)
Nearest cold water draw off (not supplied)
Service valve (not supplied)
Expansion vessel (included)
Check valve (included)
Pressure reducing valve (included)
3
To drain
MINIMUM PIPE LENGTH
Capacity
10 L
15 L
MODEL
15 - 25 mm
94 |
22 mm pipe
1.2 mm
1.8 mm
KITKW04
Expansion relief
valve
EAN13
15 mm pipe
2.7 mm
4.2 mm
Check valve
0.35 Mpa
Expansion vessel
8 L (0.1 Mpa)
8436045912992
Pressure reducing
valve
0.60 Mpa