Rointe Heating Catalogue 2023 UK-IE - Catalog - Page 93
ACCESSORIES FOR WATER HEATERS
DIMENSIONS
RTVAL001
A
(inches)
1/2"
B
(MM)
62.5
C
(MM)
125
D
(MM)
126.5
E
(MM)
81.5
F
(MM)
45
THERMOSTATIC MIXING VALVE
This accessory, installed in the hot water outlet of the heater, allows the hot water to be mixed with the cold water
coming from the main supply. The resulting mixed water is transported at a lower temperature, achieving energy
savings and minimising heat loss through the pipes until it reaches the point of use.
MODEL
RTVAL001
Control range (ºC)
30÷50
Max. operating pressure (static) (bar)
10
Max. operating pressure (dynamic) (bar)
5
Max. inlet temperature (ºC)
85ºC
Min. flow rate to ensure stable temperature (l/min)
Compatible with
4
All models
EAN13
8436045917065
EQUIVALENT OUTPUT VOLUME
Another advantage of this valve is the increase in
the volume of hot water available, with respect to
the capacity of the installed heater, defined as the
equivalent volume.
This equivalent volume represents the litres of
water available at 39 ºC, assuming that the water
inlet temperature to the boiler is 15 ºC and the set
temperature is 73 ºC.
WITHOUT VALVE (L)
WITH VALVE (L)
50
85
80
136
100
170
150
255
200
340
260
442
| 93