Rointe Heating Catalogue 2023 UK-IE - Catalog - Page 37
RADIATORS
YEARS
YEARS
GUARANTEE ON
ELECTRONICS
GUARANTEE ON
BODY
LOT20READY
TECHNICAL SPECIFICATIONS
MODELS
ORI0500RAD2
ORI0750RAD2
ORI1000RAD2
ORI1250RAD2
ORI1500RAD2
Number of elements
3
5
6
8
9
11
Nominal power (W)
500
750
1,000
1.250
1.500
1.750
Effective power (W)4
Voltage (V)
Frequency (Hz)
190
285
380
475
570
665
220-240 V ~
220-240 V ~
220-240 V ~
220-240 V ~
220-240 V ~
220-240 V ~
50
50
50
50
50
50
Current (A)
2.2
3.3
4.3
5.4
6.5
7.6
Insulation
Class I
Class I
Class I
Class I
Class I
Class I
IP24
IP24
IP24
IP24
IP24
IP24
980 x 575 x 95
IP protection
Width x height x depth (mm) 340 x 575 x 95
500 x 575 x 95
580 x 575 x 95
740 x 575 x 95
820 x 575 x 95
Installed depth (mm)
118
118
118
118
118
118
Weight (Kg)
10.9
16.7
20.6
26.3
30.1
36.9
Weight with packaging (Kg)
12.0
18.0
22.0
28.0
32.0
39.0
Recommended area (m2)
Up to 5
Up to 8
Up to 10
Up to 13
Up to 15
Up to 18
1.7
1.7
1.7
1.7
1.7
1.7
UK 3 pin
UK 3 pin
UK 3 pin
UK 3 pin
UK 3 pin
UK 3 pin
Cable length (m)
Plug type
Product includes
Brackets, template + user manual
Compatible accessories
Protection grills/covers - RKY**** , Wheel kit - RIR*01
Finishes
White RAL 9010
EAN13
8435556145172
8435556145189
8435556145196
8435556145202
DIAGRAMS
8435556145219
8435556145226
Dimensions in mm.
ORI0500RAD2
ORI0750RAD2
ORI1000RAD2
ORI1250RAD2
ORI1500RAD2
ORI1750RAD2
340
500
580
740
820
980
575
min 100
118
23
ORI1750RAD2
1) Compatible with 2.4 GHz WiFi networks. 2) Available from Q3/Q4 2023. 3) Data may vary depending on the circumstances of the electrical installation. 4) In tests carried out by independent
laboratories comparing under the same parameters a radiator with Fuzzy Logic Energy Control tech and another with Optimizer Energy Plus (the first Rointe energy control tech), a difference
in energy consumption of 6.3% was obtained. This saving allows radiators with Fuzzy Logic Energy Control to use an average power of only 38% of nominal power, which we define as the
equivalent consumption coefficient. If we multiply the nominal power by the equivalent consumption coefficient, we obtain the effective power.
| 37