Full Catalogue 2020/21 - Flipbook - Page 180
8.10
Voice Cabling Products
CW1600 Internal Phone Cable
Product Overview
The cable is designed to handle low frequency signals for short-range applications and is intended to be terminated in Insulation Displacement
Connectors (IDC), but may be soldered or wrapped. The cable is intended to take the place of Polyvinyl Chloride (PVC) sheathed cables and
will withstand similar environments with a similar working life.
There are two modes of construction; Layer for general use and Units of 20 pairs which include a 1.38mm diameter insulated earth conductor,
for use with customer distribution schemes.
Features and Benefits
•
•
•
•
Conforms to BT Specification
Constructed for use under any weather condition
Screened version also available
Available with 10, 20, 50 & 100 pairs
Product Specifications
Ordering Information
Conductor Diameter
Product Description
0.5mm
Max. Conductor Resistance
Part Number
97.8 ohm/km
CW1600 10 Pair Phone Cable + Earth White
001-008-020-10E
50 mohms
CW1600 20 Pair Phone Cable + Earth White
001-008-020-20E
Max. Capacitance - Unbalanced
500pF/500m
CW1600 50 Pair Phone Cable + Earth White
001-008-020-50E
Colour Code
BT standards
CW1600 100 Pair Phone Cable + Earth White
001-008-020-100E
Construction
Plain annealed solid copper wire;
polyethylene insulated twisted
pair, polyester tape, continuity
wire, aluminised polyester
screen, fire retardant tape, LSZH
sheath.
Insulation Resistance
Pair Specifications
Pairs
10
20
50
100
Weight
(kg/km)
113
184
381
710
Fire Performance
Test
Test Method
Value
Comment
Fume Emission
XR-F
No halogen, nitrogen, phosphorous
or sulphur containing compounds Compliant
(trace elements ≤ 0.5% w/w)
Single Cable Vertical Burn Test
BS EN 50265-2-1 IEC 60332-1:
2004
Onset of char (from top support):
> 50mm Extent of char (from top
support): < 540mm
Compliant
Bunched Cable Vertical Burn Test
BS EN 50266-2-4 BS EN 502662-5
Category C (1.5 NMV) Category D
(< 12mm diameter)
Compliant
Acid Gas Emission
BS EN 50267-2-1: 1999
Less than 5mg/g
Compliant
Smoke Emission
BS EN 61034-2: 2005
Minimum light transmittance 60%
Compliant
CPR Euroclassification
BS EN 50575-2014 AI-2016
Cca
Compliant
T: 01376 346600 E: sales@connectix.co.uk www.connectixcablingsystems.com
©2019 Connectix E&OE