HELP GUIDE - LINKS - EKF - Flipbook - Sida 24
Hemoglobin
& Hematocrit
Altair™ 240
Fully automated benchtop
chemistry analyzer
Name
Reference No.
Contents
Diabetes Care
View all
AltairTM 240
chemistry
reagents on
page 26
Altair™ 240 analyzers
Altair™ 240
chemistry analyzer with
ISE module
G6600-001
1 unit
Altair™ 240 chemistry
analyzer without ISE
module
G6000-001
1 unit
Up to 400 test per hour with
optional ISE module installed
Altair™ 240 consumables
Sports Performance
Maternal &
Women’s Health
Systemic Solution
Concentrate
A0310-001
1 x 1 liter
Cuvette Cleaner
Concentrate
A0315-002
2 x 2 liters
Sample Cups (clear)
9950-001
1 bag of
1000
Extra Wash
Cuvette Cleaner
A0300-002
1 x 2 liter
Probe Cleaner
A0305-320
9 x 36
washes
R1 Bottles Set bottles & caps
A0400-020
20 x bottles/caps
R2 Bottles Set bottles & caps
A0405-020
20 x bottles/caps
Altair 240 Tube Holders
P3140000269
1 x 10
pieces
Altair™ 240 ISE consumables
Integrated ISE module for Na+,
K+, Li+, Cl (optional)
43 reagents and 49 samples
on-board with integrated
barcode reader
Up to 30-day reagent
onboard stability
Integrated cuvette
washing station
User-friendly Windows® interface
with LIS bi-directional connectivity
Pack includes
Analyzer, universal power supply, user manual,
touch screen computer, screen lever arm,
keyboard and mouse.
Central Laboratory
ISE Reagent Pack (Cal. A & Cal. B)
S3141000290
1 Pack
ISE Cleaning Solution
S3141000292
90 mL
Chloride Electrode
S3141000286
1 each
Lithium Electrode
S3141000287
1 each
Potassium Electrode
S3141000285
1 each
Reference Electrode
S3141000288
1 each
Wavelengths ..............................(8 discrete) 340, 405, 492,
Sodium Electrode
S3141000284
1 each
Throughput......................................up to 400 tests per hour
Spacer Electrode
S3141000289
1 each
up to 240 tests per hour w/o ISE
ISE Pump Tube Kit
S31410003651
1 kit
ISE Fluid Tubing Kit
S3141000294
1 kit
ISE Urine Diluent
S3141000351
1 x 125mL
24 | Central Laboratory Analyzers
Specifications
Methodology ............................ Photometric method using
monochromatic and bichromatic measurement
Photometric linearity ........................................... 0 to 3.0 OD
505, 546, 578, 630, 700 nm
with optional ISE module or
Reagent volume ..........................................................1 – 400 μL
Size ...............................................93 (w) x 72 (d) x 60 (h) cm
36.6” x 28.3” x 23.6”
Weight................................................................... 60 kgs / 133 lbs