Stelrad Specification Book July 2024 - Catalog - Page 55
SWING
50
P+
K2
(75/65/20ºC)
Casing
Height
mm
1820
2020
Emitter
Height
mm
1800
2000
Emitter
Length
mm
Casing
Length
mm
Stelrad
UIN
400
504
38418210
500
604
38518210
1530
600
704
38618210
1836
400
504
38420210
1308
4463
500
604
38520210
1635
5579
600
704
38620210
1962
6694
Emitter
Length
mm
Casing
Length
mm
Stelrad
UIN
400
527
38418220
1476
5220
500
627
38518220
1845
6295
6264
600
727
38618220
2214
7554
400
527
38420220
1584
5405
500
627
38520220
1980
6756
600
727
38620220
2376
8107
Heat output
Watts
Btu/hr
1224
4176
Heat output
Watts
Btu/hr
5036
t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20ºC. If you have a low temperature
heat source you may wish to consider t40 or t30 output (see your installer or system designer or download from www.stelrad.com).
For EN442 data, technical and installation information please visit our website: www.stelrad.com and search product downloads.
For systems not operating at DeltaT 50 the correction factors table on page 104 should be applied.
We recommend TRV Valves to complete the
look. See page 107 for more information.
COLOUR OPTIONS
Comes in White as standard (RAL 9016). Please refer to page 108 for colour options.
All colour radiators have up to an 8 week lead time, and when a coloured radiator or radiators have been ordered they cannot be cancelled or returned.
For more information on colour radiator prices please contact your local merchant.
12
BAR
WORKING
PRESSURE
55