Stelrad Specification Book July 2024 - Catalog - Page 29
COMPACT WITH STYLE K3
50
K3
(75/65/20ºC)
Height
mm
300
500
600
700
Length
mm
Sections
Stelrad
UIN
Watts
1000
Heat output
30
7433310
1287
4391
2000
60
7433320
2574
8783
600
18
7453306
1187
4050
700
21
7453307
1385
4726
800
24
7453308
1583
5401
900
27
7453309
1781
6077
1000
30
7453310
1979
6753
1100
33
7453311
2177
7428
Btu/hr
1200
36
7453312
2375
8104
1400
42
7453314
2771
9455
10803
1600
48
7453316
3166
1800
54
7453318
3562
12154
2000
60
7453320
3958
13505
2400
72
7453324
4750
16208
400
12
7463304
912
3112
500
15
7463305
1140
3890
600
18
7463306
1368
4668
700
21
7463307
1596
5446
800
24
7463308
1824
6224
900
27
7463309
2052
7002
1000
30
7463310
2280
7779
1100
33
7463311
2508
8558
1200
36
7463312
2736
9336
1400
42
7463314
3192
10892
1600
48
7463316
3648
12447
1800
54
7463318
4104
14003
2000
60
7463320
4560
15559
2400
72
7463324
5472
18671
500
15
7473305
1277
4357
600
18
7473306
1532
5227
700
21
7473307
1787
6098
800
24
7473308
2042
6968
900
27
7473309
2298
7841
1000
30
7473310
2553
8711
1100
33
7473311
2808
9581
10455
1200
36
7473312
3064
1400
42
7473314
3574
12195
1600
48
7473316
4085
13939
1800
54
7473318
4595
15679
2000
60
7473320
5106
17422
t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20ºC. If you have a low temperature
heat source you may wish to consider t40 or t30 output (see your installer or system designer or download from www.stelrad.com).
For EN442 data, technical and installation information please visit our website: www.stelrad.com and search product downloads.
For systems not operating at DeltaT 50 the correction factors table on page 104 should be applied.
Piping connections are the same as the Stelrad Compact.
BAR
WORKING
PRESSURE
29