Stelrad Softline Series Brochure July 2024 - Flipbook - Page 29
SOFTLINE COLUMN HORIZONTAL
50
(75/65/20ºC)
2 COLUMN
Height
mm
500
600
Length
mm
Stelrad
UIN
Watts
Heat output
628
563012
499
1703
858
563013
691
2358
1042
563014
845
2884
1272
563015
1037
3539
628
563028
589
2010
858
563029
815
2782
1042
563030
997
3403
1272
563031
1223
4174
3 COLUMN
Height
mm
300
500
600
750
Btu/hr
4 COLUMN
Length
mm
Stelrad
UIN
Watts
Heat output
Btu/hr
Length
mm
Stelrad
UIN
444
563000
288
983
444
563007
377
1287
628
563001
416
1420
628
563008
545
1860
2573
Watts
Heat output
Btu/hr
858
563002
576
1966
858
563009
754
1042
563003
704
2403
1042
563010
922
3147
1272
563004
864
2949
1272
563011
1131
3860
-
1456
563005
992
3386
-
-
-
1870
563006
1280
4369
-
-
-
-
444
563016
464
1584
444
563023
608
2075
3000
628
563017
671
2290
628
563024
879
858
563018
929
3171
858
563025
1217
4154
1042
563019
1135
3874
1042
563026
1487
5075
6229
1272
563020
1393
4754
1272
563027
1825
1456
563021
1600
5461
-
-
-
-
1870
563022
2064
7044
-
-
-
-
444
563032
548
1870
444
563039
718
2451
628
563033
792
2703
628
563040
1037
3539
858
563034
1096
3741
858
563041
1436
4901
1042
563035
1340
4573
1042
563042
1756
5993
7355
1272
563036
1644
5611
1272
563043
2155
1456
563037
1888
6444
-
-
-
-
1870
563038
2436
8314
-
-
-
2993
444
-
-
-
444
563049
877
628
-
-
-
628
563050
1266
4321
858
563044
1337
4563
858
563051
1753
5983
1042
563045
1635
5580
1042
563052
2143
7314
1272
563046
2006
6846
1272
563053
2630
8976
1456
563047
2303
7860
1456
-
-
-
1870
563048
2972
10143
1870
-
-
-
t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20ºC. If you have a low temperature
heat source you may wish to consider t40 or t30 output (see your installer or system designer or download from www.stelrad.com).
Due to production tolerances, the length of the product and therefore the tap centres could contain a variation of +/- 1.5% of the overall stated length.
For EN442 data, technical and installation information please visit our website: www.stelrad.com and search product downloads.
For systems not operating at DeltaT 50 the correction factors table on page 78 should be applied.
Floor mounting brackets are available, for more information see page 80.
BAR
WORKING
PRESSURE
AUGMENTED
REALITY APP
AVAILABLE
IN STOCK
Traffic
white
29