Aquatechnica brochure flipbook pages - Flipbook - Page 11
TECHNICAL POOLS - COMPETITION AND DIVING POOLS I POOL TANK AND WALL TILES
Brown
Beige
Black
111
COLOUR
811
COLOUR
911
COLOUR
121
COLOUR
821
COLOUR
921
COLOUR
141
COLOUR
841
COLOUR
931
COLOUR
151
COLOUR
861
COLOUR
951
COLOUR
171
COLOUR
871
COLOUR
971
COLOUR
191
COLOUR
881
COLOUR
991
COLOUR
Standard DIN 51130: 2004
DIN 51130 uses heavily-cleated EN:ISO 20345 safety boots with motor oil contamination. Testing of floor coverings; determination of the anti-slip
properties; workrooms and fields of activities with slip danger; walking method; ramp test – fully recognised and adopted in the UK.
DIN 51130 R-Value Slipperiness Classification
Classification
Slip angle (°)
Description
Uses
R9
6-10
Low Friction / High Slip Risk
Suitable for dry internal domestic floors,
e.g. kitchens and hallways
R10
10-19
R11
19-27
Medium Friction / Moderate Slip Risk
Suitable for internal domestic floors subject
to occasional wetting, e.g. bathrooms
High Friction / Low Slip Risk
Suitable for external areas, e.g. patios and
walkways, public toilets
R12
27-35
High Friction / Low Slip Risk
Suitable for external areas, e.g. patios and
walkways, public toilets
R13
35+
High Friction / Low Slip Risk
Suitable for slopes and high-resistance requirement external
areas, e.g. sloped walkways in wet areas
Standard DIN 51097: 1992
A standard that tests slip resistance of flooring in barefoot conditions using soapy water as a contamination. DIN 51097 testing is suited to swimming
pools and wet rooms, areas generally only accessible when barefoot. The test provides a good indication of wet slip resistance.
DIN 51130 R-Value Slipperiness Classification
Rating value ABC
Slip angle (°)
Slip risk
Uses
A
12-17
Hight/moderate
Dry barefoot areas
B
18-23
Moderate/low
Pool surrounds & showers
C
24+
Low
Wet ramps, walk through pools & jacuzzi floors
SEE DATASHEET FOR MORE INFORMATION