UK VRF GEN 24 - Flipbook - Page 95
R410A
VRF SYSTEMS INDEX
VRF SYSTEMS
Hydrokit for ECOi, water at 45 °C · R410A
Connect the Hydrokit to your VRF system, together with other indoor units.
Total system performs high energy efficiency through heat recovering
operation, and it gives an advantage for sustainability related assessment
methods, such as BREEAM in UK.
COMPATIBLE WITH ALL PANASONIC CONNECTIVITY SOLUTIONS. FOR
DETAILED INFORMATION GO TO THE CONTROL SYSTEMS SECTION
Indoor unit
S-80MW1E5
Voltage
Power supply
V
Phase
Frequency
S-125MW1E5
230
230
Single phase
Single phase
Hz
50
50
Cooling capacity
kW
8,0
12,5
Heating capacity
kW
9,0
14,0
Maximum temperature
°C
~45 / ~65 1)
~45 / ~65 1)
mm
892 x 502 x 353
892 x 502 x 353
Inch
R1¼
R1¼
DC motor (A class)
DC motor (A class)
Dimension
HxWxD
Water pipe connector
Water pump (built-in)
Water flow rate
Piping diameter
Cool
L/min
22,90
35,80
Heat
L/min
25,80
40,10
Liquid
Inch (mm)
3/8 (9,52)
3/8 (9,52)
Gas
Inch (mm)
5/8 (15,88)
5/8 (15,88)
Drain
Cool
Operation range
Heat
15 ~ 17 (inner size)
15 ~ 17 (inner size)
Ambient
mm
°C
+10 ~ +43
+10 ~ +43
Water
°C
+5 ~ +20
+5 ~ +20
Ambient
°C
-20 ~ +43
-20 ~ +43
Water
°C
+25 ~ +45
+25 ~ +45
Connectable system
3-Pipe (heat recovery type) VRF System (system capable up to 48 HP)
Maximum Indoor ratio (connectable hydrokit module capacity ratio)
Total indoor unit + Hydrokit capacity: up to 130% (** ~ **% vs total outdoor unit capacity)
1) Maximum 45 °C by refrigerant circuit (heat pump cycle), over 45 °C is provided by electric heater operation.
Accessories
CZ-RTC5B
Wired remote controller with Econavi function
Basic principle and advantage.
Hydrokit module provides hot water by using waste heat
that is recovered from standard air-conditioning indoor
unit in cooling mode.
Technical focus
· Only with 3-Pipe ECOi EX MF3 Series outdoor units
· Remote controller CZ-RTC5B common use with DX coil
indoor units PACi and ECOi
Hydrokit control function / CZ-RTC5B
· CZ-RTC5B can be used for hydrokit and also normal
indoor unit. CZ-RTC5B checks the type of connected unit
and switches between hydrokit and air conditioner
display automatically
· Hydrokit mode (tank or air conditioning mode) is set
during initial startup
Overview: hydromodule in VRF system
· Multiple hydromodule connection in same circuit is
available
· The mode of each module can be individually set from
either hot water or space heating / cooling (once set the
units cannot operate in another mode, resetting will be
required)
· 3-Pipe control solenoid valve kit is necessary for each
indoor unit and hydromodule
Max 65 °C (with E-heater).
Water heating
Hot water
supply
3-Pipe ECOi EX
MF3 Series
outdoor unit
Heat recovery
from standard
indoor units
Max 45 °C
space heating
* Cold water also available.
Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
95