UK VRF GEN 24 - Flipbook - Page 61
VRF SYSTEMS
VRF SYSTEMS INDEX
Quick start up and great heating capacity at low ambient temperature.
Waste heat from gas engine is utilized to raise
temperature faster than electric VRF systems.
This contributes great heating capacity at extremely low
ambient temperature.
ECO G
Room temperature
25
24
24
23
23
22
22
21
21
20
20
19
19
18
VRF (VRF)
Room temperature
25
Lowest nitrogen oxide emissions.
The ECO G VRF systems have low nitrogen oxide
emissions. In a pioneering development, the Panasonic
ECO G features a brand lean-burn combustion system that
utilizes air fuel ratio feedback control to reduce NOx
emissions to an all time low.
Water chiller option.
Our ECO G system is also available with a water heat
exchanger option, which can be combined with individual
outdoor units or as part of a DX chilled water mix of indoor
units. The system can be operated via a BMS system or a
Panasonic supplied control panel, with chilled water set
points from
-15 °C ~ +15 °C and heating set points 35 °C ~ +55 °C.
Defrost
operation
18
Time
Time
Application
Application
Condition
Hotel
High DHW demand
Hotel
Needs to warm up swimming pool
Office
Winery
Any building
ECO G
✔
Energy recovery of ECO G system can fulfill different requirement
Quick start up is necessary
✔
Speed of start up is quicker than VRF system
1) Outlet water demand at specific temperature
2) Needs high amount of power temporary (not
every month)
✔
1) Chiller application with hydro module (ECO G + WHE) can make
this special process
2) Running cost can be saved since fixed Gas tariff per month is
cheaper than fixed electric tariff.
In a city with power restriction
✔
- No need an additional power transformer
- Space and cost can be saved
At extremely low ambient condition
✔
Heating capacity is kept up to -20 °C without defrost process
Project case studies
Savills HQ Dublin and Google Block R. Ireland.
ECO G 3-Pipe units with a 243 kW load.
The project has been such a success that it has recently been
awarded a Panasonic PRO Award for Best Contribution of efficient
projects within Europe.
Thomas Cook’s Sunprime Atlantic View resort.
A holiday resort in the Canaries. Spain.
229 rooms plus full spa and swimming pool facility.
CAPITA call centre. UK.
11 ECO G 3-Pipe units.
Over 150 indoor units in meeting rooms and open-plan areas.
Intelligent touch screen controller, the CZ-256ESMC2.
French winery Gennevilliers, France.
ECO G 3-Pipe units. One of the best solution utilized our ECO G
solution for wine production process.
61