UK VRF GEN 24 - Flipbook - Page 56
R410A
GENERAL INDEX
3-Pipe ECOi EX MF3 Series
Simultaneous heating and cooling operation with heat recovery type.
The 3-Pipe ECOi EX MF3 Series is one of the most advanced VRF systems.
Not only highly efficient performance for simultaneous heating and cooling, but
also sophisticated installation and maintenance capability.
HP
4,85
SCOP
8 HP
10 HP
12 HP
14 HP
16 HP
U-8MF3E8
U-10MF3E8
U-12MF3E8
U-14MF3E8
U-16MF3E8
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
Three phase
Three phase
Three phase
Three phase
Three phase
Hz
50
50
50
50
50
Cooling capacity
kW
22,4
28,0
33,5
40,0
45,0
EER 1)
W/W
Current
A
Input power
Heating capacity
COP 1)
Outdoor unit
Voltage
Power supply
V
Phase
Frequency
5,11
4,72
3,91
3,70
3,49
7,16 - 6,80 - 6,55
9,90 - 9,41 - 9,07
3,19 - 13,20 - 12,70
18,20 - 17,30 - 16,70
21,30 - 20,20 - 19,50
kW
4,38
5,93
8,57
10,80
12,90
kW
25,0
31,5
37,5
45,0
50,0
W/W
5,25
5,17
4,51
4,21
4,17
Current
A
7,78 - 7,39 - 7,12
10,20 - 9,66 - 9,31
13,40 - 12,80 - 12,30
18,10 - 17,20 - 16,50
20,00 - 19,00 - 18,30
Input power
kW
4,76
6,09
8,32
10,70
12,00
Starting current
A
1,00
1,00
1,00
2,00
2,00
External static pressure (Max)
Pa
80
80
80
80
80
Air flow
m³/min
210
220
232
232
232
Sound pressure
Normal mode
dB(A)
54,0
57,0
60,0
61,0
62,0
Silent mode 1 / 2
dB(A)
51,0 / 49,0
54,0 / 52,0
57,0 / 55,0
58,0 / 56,0
59,0 / 57,0
Sound power
Normal mode
dB(A)
Dimension
HxWxD
mm
261
262
286
334
334
Liquid
Inch (mm)
3/8 (9,52) / 1/2 (12,70)
3/8 (9,52) / 1/2 (12,70)
1/2 (12,70) / 5/8 (15,88)
1/2 (12,70) / 5/8 (15,88)
1/2 (12,70) / 5/8 (15,88)
Discharge
Inch (mm)
5/8 (15,88) / 3/4 (19,05)
3/4 (19,05) / 7/8 (22,22)
3/4 (19,05) / 7/8 (22,22)
7/8 (22,22) / 1 (25,40)
7/8 (22,22) / 1 (25,40)
Suction
Inch (mm)
3/4 (19,05) / 7/8 (22,22)
7/8 (22,22) / 1 (25,40)
1 (25,40) / 1-1/8 (28,58)
1 (25,40) / 1-1/8 (28,58)
1-1/8(28,58)/1-1/4(31,75)
Net weight
76,0
78,0
81,0
82,0
82,0
1 842 x 1 180 x 1 000
1 842 x 1 180 x 1 000
1 842 x 1 180 x 1 000
1 842 x 1 180 x 1 000
1 842 x 1 180 x 1 000
kg
Piping diameter 2)
Balance
Refrigerant (R410A) / CO2 Eq.
Maximum allowable indoor / outdoor
capacity ratio
Operating range
Inch (mm)
kg / T
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
6,80 / 14,1984
6,80 / 14,1984
8,30 / 17,3304
8,30 / 17,3304
8,30 / 17,3304
%
50 ~ 150
50 ~ 150
50 ~ 150
50 ~ 150
50 ~ 150
Cool Min ~ Max
°C
-10 ~ +52
-10 ~ +52
-10 ~ +52
-10 ~ +52
-10 ~ +52
Heat Min ~ Max
°C
-20 ~ +18
-20 ~ +18
-20 ~ +18
-20 ~ +18
-20 ~ +18
Simultaneous op.
°C
-10 ~ +24
-10 ~ +24
-10 ~ +24
-10 ~ +24
-10 ~ +24
ErP data 3)
SEER 4)
ηs,c
7,02
7,05
6,39
6,69
6,02
277,7%
278,9%
252,7%
264,4%
237,7%
SCOP 4)
ηs,h
4,85
4,25
4,27
4,13
3,81
190,9%
166,8%
167,8%
162,1%
149,3%
1) EER and COP calculation is based in accordance to EN14511. 2) Piping diameter under 90 m for ultimate indoor unit / over 90 m for ultimate indoor unit (if the longest piping equivalent length exceeds 90 m,
increase the sizes of the main tubes by 1 rank for gas tubes and liquid tubes). 3) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for F2 type variable static pressure hide-away indoor units.
4) SEER / SCOP is calculated based on the seasonal space cooling / heating efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.
Solenoid valve kit
KIT-P56HR3
3-Pipe control solenoid valve kit (up to 5,6 kW)
CZ-P56HR3
Solenoid valve kit (up to 5,6 kW)
CZ-CAPE2
3-Pipe control PCB
KIT-P160HR3
3-Pipe control solenoid valve kit (from 5,6 to 16,0 kW)
CZ-P160HR3
Solenoid valve kit (from 5,6 kW to 16,0 kW)
CZ-CAPE2
3-Pipe control PCB
CZ-CAPEK2 5)
3-Pipe control PCB for wall-mounted
3-Pipe control box kit
CZ-P456HR3
4 ports 3 pipe box (up to 5,6 kW per port)
CZ-P656HR3
6 ports 3 pipe box (up to 5,6 kW per port)
CZ-P856HR3
8 ports 3 pipe box (up to 5,6 kW per port)
CZ-P4160HR3
4 ports 3 pipe box (up to 16,0 kW per port)
5) Available for S-45/56/73/106MK2E5B.
-20 °C
HIGH COP
56
· Achieving SCOP 4,85 top class in the industry (LOT21
Seasonal heating efficiency value for 8 HP outdoor unit)
· Simultaneous cooling and heating operation with up to 39
indoor units
· Slim heat recovery boxes with just 200 mm height fit with
the ceiling space limited in hotel applications
HEATING MODE
Technical focus
· High SEER / SCOP at full Load capacity (follows LOT21)
· Eurovent certified EER / COP
· Standardisation of outdoor unit to one compact casing
size
· Connection of up to 52 indoor units
· High external static pressure 80 Pa with an efficient fan
shape, fan guard, motor, and casing
· Silent outdoor unit operation: Minimum 54 dB(A) for 8 HP
· Bluefin coil coating as standard