UK VRF GEN 24 - Flipbook - Page 50
R410A
GENERAL INDEX
2-Pipe ECOi EX ME2 Series space saving model combination from 22 to 80 HP
HP
Outdoor unit
Voltage
Power supply
V
Phase
22 HP
24 HP
26 HP
28 HP
30 HP
32 HP
34 HP
U-10ME2E8
U-12ME2E8
U-10ME2E8
U-12ME2E8
U-14ME2E8
U-16ME2E8
U-14ME2E8
U-12ME2E8
U-12ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-20ME2E8
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
Three phase
Three phase
Three phase
Three phase
Three phase
Three phase
Three phase
Hz
50
50
50
50
50
50
50
Cooling capacity
kW
61,5
68,0
73,0
78,5
85,0
90,0
96,0
EER 1)
W/W
Frequency
SEER 2)
4,13
3,93
3,80
3,69
3,68
3,52
3,56
6,90
6,86
6,62
6,60
6,88
6,55
7,21
Current
A
24,30-23,10-22,30
28,00-26,60-25,60
31,70-30,10-29,00
34,80-33,10-31,90
38,60-36,60-35,30
42,30-40,20-38,70
44,10-41,90-40,40
Input power
kW
14,90
17,30
19,20
21,30
23,10
25,60
27,00
Heating capacity
kW
69,0
76,5
81,5
87,5
95,0
100,0
108,0
COP 1)
W/W
4,76
4,69
4,55
4,56
4,48
4,42
4,17
4,53
4,78
4,16
4,29
4,13
4,09
4,14
SCOP 2)
Current
A
23,90-22,70-21,90
26,60-25,30-24,40
29,90-28,40-27,40
31,70-30,10-29,00
35,40-33,60-32,40
37,70-35,80-34,60
42,80-40,60-39,20
Input power
kW
14,50
16,30
17,90
19,20
21,20
22,60
25,90
Starting current
A
2,00
2,00
3,00
3,00
4,00
4,00
4,00
External static pressure (Max)
Pa
80
80
80
80
80
80
80
Air flow
m³/min
456
464
456
464
464
464
637
63,0 / 60,0
Sound pressure
Normal / Silent mode
dB(A)
61,0 / 58,0
62,0 / 59,0
62,5 / 59,5
63,5 / 60,5
63,5 / 60,5
64,0 / 61,0
Sound power
Normal mode
dB(A)
82,0
83,0
83,5
84,5
84,5
85,0
84,0
Dimension /
Net weight
HxWxD
mm / kg
1 842 x 2 010
x 1 000 / 480
1 842 x 2 420
x 1 000 / 540
1 842 x 2 010
x 1 000 / 525
1 842 x 2 420
x 1 000 / 585
1 842 x 2 420
x 1 000 / 630
1 842 x 2 420
x 1 000 / 630
1 842 x 2 780
x 1 000 / 690
Liquid
Inch (mm)
5/8 (15,88) /
3/4 (19,05)
5/8 (15,88) /
3/4 (19,05)
3/4 (19,05) /
7/8 (22,22)
3/4 (19,05) /
7/8 (22,22)
3/4 (19,05) /
7/8 (22,22)
3/4 (19,05) /
7/8 (22,22)
3/4 (19,05) /
7/8 (22,22)
Gas
Inch (mm)
1-1/8 (28,58) /
1-1/4 (31,75)
1-1/8 (28,58) /
1-1/4 (31,75)
1-1/4 (31,75) /
1-1/2 (38,10)
1-1/4 (31,75) /
1-1/2 (38,10)
1-1/4 (31,75) /
1-1/2 (38,10)
1-1/4 (31,75) /
1-1/2 (38,10)
1-1/4 (31,75) /
1-1/2 (38,10)
Balance
Inch (mm)
Piping diameter 3)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
13,90 / 23,3856
16,60 / 34,6608
13,90 / 29,0232
16,60 / 34,6608
16,60 / 34,6608
16,60 / 34,6608
17,80 / 37,1664
%
50 ~ 130 (200)
50 ~ 130 (200)
50 ~ 130 (200)
50 ~ 130 (200)
50 ~ 130 (200)
50 ~ 130 (200)
50 ~ 130 (200)
Cool Min ~ Max
°C
-10 ~ +52
-10 ~ +52
-10 ~ +52
-10 ~ +52
-10 ~ +52
-10 ~ +52
-10 ~ +52
Heat Min ~ Max
°C
-25 ~ +18
-25 ~ +18
-25 ~ +18
-25 ~ +18
-25 ~ +18
-25 ~ +18
-25 ~ +18
Refrigerant (R410A) / CO2 Eq.
kg / T
Maximum allowable indoor / outdoor
capacity ratio 4)
Operating range
HP
Outdoor unit
Voltage
Power supply
V
Phase
36 HP
38 HP
40 HP
42 HP
44 HP
46 HP
48 HP
U-16ME2E8
U-18ME2E8
U-20ME2E8
U-10ME2E8
U-12ME2E8
U-14ME2E8
U-16ME2E8
U-20ME2E8
U-20ME2E8
U-20ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
U-16ME2E8
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
Three phase
Three phase
Three phase
Three phase
Three phase
Three phase
Three phase
Hz
50
50
50
50
50
50
50
Cooling capacity
kW
101,0
107,0
113,0
118,0
124,0
130,0
135,0
EER 1)
W/W
Frequency
SEER 2)
3,42
3,42
3,34
3,69
3,62
3,62
3,52
6,86
7,32
7,16
6,57
6,60
6,70
6,55
63,40-60,20-58,10
Current
A
47,70-45,30-43,70
50,60-48,10-46,30
54,10-51,40-49,50
52,80-50,20-48,40
56,00-53,20-51,30
59,90-56,90-54,90
Input power
kW
25,9
31,3
33,8
32,0
34,3
35,9
38,4
Heating capacity
kW
113,0
119,0
127,0
132,0
138,0
145,0
150,0
COP 1)
W/W
SCOP 2)
4,14
4,13
3,92
4,49
4,50
4,46
4,42
4,06
4,14
4,13
4,11
4,21
4,12
4,09
Current
A
44,60-42,40-40,80
47,10-44,70-43,10
52,40-49,80-48,00
49,10-46,60-44,90
50,70-48,20-46,40
54,30-51,50-49,7
56,60-53,80-51,8
Input power
kW
27,30
28,80
32,40
29,40
30,70
32,50
33,90
Starting current
A
4,00
4,00
4,00
5,00
5,00
6,00
6,00
External static pressure (Max)
Pa
80
80
80
80
80
80
80
Air flow
m³/min
637
810
810
688
696
696
696
66,0 / 63,0
Sound pressure
Normal / Silent mode
dB(A)
63,5 / 60,5
62,5 / 59,5
63,0 / 60,0
65,0 / 62,0
65,5 / 62,5
65,5 / 62,5
Sound power
Normal mode
dB(A)
84,5
83,5
84,0
86,0
86,5
86,5
87,0
1 842 x 3 140
x 1 000 / 750
1 842 x 3 140
x 1 000 / 750
1 842 x 3 250
x 1 000 / 840
1 842 x 3 660
x 1 000 / 900
1 842 x 3 660
x 1 000 / 945
1 842 x 3 660
x 1 000 / 945
Dimension /
Net weight
Piping diameter 3)
HxWxD
mm / kg
1 842 x 2 780
x 1 000 / 690
Liquid
Inch (mm)
3/4 (19,05) /
7/8 (22,22)
3/4 (19,05) /
7/8 (22,22)
3/4 (19,05) /
7/8 (22,22)
3/4 (19,05) /
7/8 (22,22)
3/4 (19,05) /
7/8 (22,22)
3/4 (19,05) /
7/8 (22,22)
3/4 (19,05) /
7/8 (22,22)
Gas
Inch (mm)
1-1/2 (38,10) /
1-5/8 (41,28)
1-1/2 (38,10) /
1-5/8 (41,28)
1-1/2 (38,10) /
1-5/8 (41,28)
1-1/2 (38,10) /
1-5/8 (41,28)
1-1/2 (38,10) /
1-5/8 (41,28)
1-1/2 (38,10) /
1-5/8 (41,28)
1-1/2 (38,10) /
1-5/8 (41,28)
Balance
Inch (mm)
Refrigerant (R410A) / CO2 Eq.
kg / T
Maximum allowable indoor / outdoor
capacity ratio 4)
Operating range
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
17,80 / 37,1664
19,00 / 39,672
19,00 / 39,672
22,20 / 46,3536
24,90 / 51,9912
24,90 / 51,9912
24,90 / 51,9912
%
50 ~ 130 (200)
50 ~ 130 (200)
50 ~ 130 (200)
50 ~ 130 (200)
50 ~ 130 (200)
50 ~ 130 (200)
50 ~ 130 (200)
Cool Min ~ Max
°C
-10 ~ +52
-10 ~ +52
-10 ~ +52
-10 ~ +52
-10 ~ +52
-10 ~ +52
-10 ~ +52
Heat Min ~ Max
°C
-25 ~ +18
-25 ~ +18
-25 ~ +18
-25 ~ +18
-25 ~ +18
-25 ~ +18
-25 ~ +18
1) EER and COP calculation is based in accordance to EN14511. 2) SEER / SCOP is calculated based on the seasonal space cooling / heating efficiency “η” values of the COMMISSION REGULATION (EU)
2016/2281. SEER, SCOP = (η + Correction) × PEF. 3) Piping diameter under 90 m for ultimate indoor unit / over 90 m for ultimate indoor unit (if the longest piping equivalent length exceeds 90 m, increase the
sizes of the main tubes by 1 rank for gas tubes and liquid tubes). 4) If the following conditions are satisfied, the effective range is above 130% and below 200%: A. Obey the limited number of connectable indoor
units. B. The lower limit of operating range for heating outdoor temperature is limited to -10 °C WB (standard -25 °C WB). C. Simultaneous operation is limited to less than 130% of connectable indoor units.
50