UK VRF GEN 24 - Flipbook - Page 47
R410A
VRF SYSTEMS INDEX
VRF SYSTEMS
2-Pipe ECOi EX ME2 Series
A VRF system delivering energy-saving performance,
powerful operation, reliability and comfort, surpassing
anything previously possible. It represents a true
paradigm shift in air conditioning solutions.
VRF with outstanding energy-saving performance and
powerful operation SEER 7,56 (18 HP model).
HP
8 HP
10 HP
12 HP
14 HP
16 HP
18 HP
20 HP
U-8ME2E8
U-10ME2E8
U-12ME2E8
U-14ME2E8
U-16ME2E8
U-18ME2E8
U-20ME2E8
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
Three phase
Three phase
Three phase
Three phase
Three phase
Three phase
Three phase
Hz
50
50
50
50
50
50
50
kW
22,4
28,0
33,5
40,0
45,0
50,0
56,0
Outdoor unit
Voltage
Power supply
V
Phase
Frequency
Cooling capacity
EER 1)
W/W
4,70
4,37
3,96
3,88
3,52
3,52
3,35
ESEER
W/W
9,33
8,67
7,94
7,73
7,19
6,95
6,18
Current
A
17,40-16,50-15,90
21,10-20,10-19,40
23,20-22,00-21,20
26,70-25,40-24,50
Input power
kW
7,79 - 7,40 - 7,14 10,70-10,20-9,80 13,70-13,00-12,50
4,77
6,41
8,47
10,30
12,80
14,20
16,70
Heating capacity
kW
25,0
31,5
37,5
45,0
50,0
56,0
63,0
COP 1)
W/W
5,13
4,76
4,73
4,56
4,42
4,38
3,94
Current
A
7,96 - 7,56 - 7,29
11,10-10,50-10,10
12,90-12,30-11,80
16,60-15,80-15,20
18,90-17,90-17,30
21,10-20,10-19,40
25,90-24,60-23,70
Input power
kW
4,87
6,62
7,92
9,86
11,30
12,80
16,00
Starting current
A
1,00
1,00
1,00
2,00
2,00
2,00
2,00
External static pressure (Max)
Pa
80
80
80
80
80
80
80
Air flow
m³/min
224
224
232
232
232
405
405
Normal mode
dB(A)
54
56
59
60
61
59
60
Silent mode
dB(A)
51
53
56
57
58
56
57
Normal mode
dB(A)
75
77
80
81
82
80
81
1 842 x 770
x 1 000
1 842 x 770
x 1 000
1 842 x 1 180
x 1 000
1 842 x 1 180
x 1 000
1 842 x 1 180
x 1 000
1 842 x 1 540
x 1 000
1 842 x 1 540
x 1 000
Sound pressure
Sound power
Dimension
HxWxD
mm
Net weight
kg
Piping diameter 2)
210
210
270
315
315
375
375
Liquid
Inch (mm)
3/8 (9,52) /
1/2 (12,70)
3/8 (9,52) /
1/2 (12,70)
1/2 (12,70) /
5/8 (15,88)
1/2 (12,70) /
5/8 (15,88)
1/2 (12,70) /
5/8 (15,88)
5/8 (15,88) /
3/4 (19,05)
5/8 (15,88) /
3/4 (19,05)
Gas
Inch (mm)
3/4 (19,05) /
7/8 (22,22)
7/8 (22,22) /
1 (25,40)
1 (25,40) /
1-1/8 (28,58)
1 (25,40) /
1-1/8 (28,58)
1-1/8 (28,58) /
1-1/4 (31,75)
1-1/8 (28,58) /
1-1/4 (31,75)
1-1/8 (28,58) /
1-1/4 (31,75)
Balance
Inch (mm)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
Refrigerant (R410A) / CO2 Eq
kg / T
5,60 / 11,6928
5,60 / 11,6928
8,30 / 17,3304
8,30 / 17,3304
8,30 / 17,3304
9,50 / 19,836
9,50 / 19,836
Maximum allowable indoor / outdoor
capacity ratio 3)
%
50 ~ 130 (200)
50 ~ 130 (200)
50 ~ 130 (200)
50 ~ 130 (200)
50 ~ 130 (200)
50 ~ 130 (200)
50 ~ 130 (200)
Operating range
Cool Min ~ Max
°C
-10 ~ +52
-10 ~ +52
-10 ~ +52
-10 ~ +52
-10 ~ +52
-10 ~ +52
-10 ~ +52
Heat Min ~ Max
°C
-25 ~ +18
-25 ~ +18
-25 ~ +18
-25 ~ +18
-25 ~ +18
-25 ~ +18
-25 ~ +18
ErP data 4)
SEER 5)
ηs,c
7,43
6,96
6,74
7,23
6,43
7,56
7,03
294,3%
275,4%
266,6%
286,0%
254,3%
299,2%
278,2%
SCOP 5)
ηs,h
4,79
4,27
4,72
4,28
4,05
4,29
4,09
188,4%
167,6%
185,8%
168,2%
159,0%
168,7%
160,4%
1) EER and COP calculation is based in accordance to EN14511. 2) Piping diameter under 90 m for ultimate indoor unit / over 90 m for ultimate indoor unit (if the longest piping equivalent length exceeds 90 m,
increase the sizes of the main tubes by 1 rank for gas tubes and liquid tubes). 3) If the following conditions are satisfied, the effective range is above 130% and below 200%: A. Obey the limited number of
connectable indoor units. B. The lower limit of operating range for heating outdoor temperature is limited to -10 °C WB (standard -25 °C WB). C. Simultaneous operation is limited to less than 130% of
connectable indoor units. 4) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for F2 type variable static pressure hide-away indoor units. 5) SEER / SCOP is calculated based on the seasonal space
cooling / heating efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.
Technical focus
· Twin rotary Inverter compressor
· High performance at extreme conditions
· Outstanding efficiency and comfort
· Extraordinary partial load, SEER and SCOP
· SEER and SCOP following EN-14825
· Oil recovery intelligent control
ALL INVERTER
COMPRESSORS
-25 °C
52 °C
HEATING MODE
COOLING MODE
· Top comfort
· Superior flexibility
· Bluefin full line up EX
· Extremely high capacity at -20 °C and unique heating
capacity at -25 °C
· Smooth exhaust flow by bell-mouth
BLUEFIN
Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.