UK VRF GEN 24 - Flipbook - Page 100
R32
R410A
GENERAL INDEX
NEW energy recovery ventilation with DX coil - HRPT Series · R32 / R410A
· Dual flow ventilation with EC fan, featuring high efficiency heat recovery (>85% η)
· 2 types of polypropylene heat exchanger (high efficiency and sensible) with
counter-current flows and integrated bypass as standard
New
· Modbus connection available
2024
COMPATIBLE WITH ALL PANASONIC CONNECTIVITY SOLUTIONS. FOR
DETAILED INFORMATION GO TO THE CONTROL SYSTEMS SECTION
Indoor unit with high-efficiency heat exchanger
Voltage
Power supply
Phase
Frequency
PAW-HRPT40HX
PAW-HRPT80HX
PAW-HRPT120HX
PAW-HRPT160HX
230
230
230
230
380
Single phase
Single phase
Single phase
Single phase
Three phase
V
Hz
50
Heat recovery ventilation 1)
50
50
PAW-HRPT200HX
50
50
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
47,6
Temperature efficiency
%
60,9
49,5
59,2
47,6
60,3
48,8
61,0
49,6
59,2
Enthalpy efficiency
%
75,7
51,6
73,1
48,9
73,6
50,7
74,3
50,8
73
Weight
kg
Indoor unit with sensible heat exchanger
Voltage
Power supply
Frequency
120
135
150
180
PAW-HRPT40
PAW-HRPT80
PAW-HRPT120
PAW-HRPT160
PAW-HRPT200
230
230
230
230
380
Single phase
Single phase
Single phase
Single phase
Three phase
V
Phase
Hz
50
Heat recovery ventilation 1)
Temperature efficiency
%
Weight
kg
48,8
70
50
50
50
50
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
86,1
86,6
84,3
84,7
82,9
83,5
83,9
84,2
81,3
82,0
67
117
132
147
177
Common data
DX coil
Total / Sensible capacity
kW
Maximum input current
A
Sound pressure @1 m / @3 m
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
2,5
3,0
5,0
6,0
7,0
8,1
10,0
12,5
12,5
Heating
14,0
1,5
2,2
4,1
4,4
3,3
dB(A)
41 / 35
51 / 43
42 / 36
49 / 41
57 / 49
Air flow
High
m³/h
500
800
1 500
1 700
2 450
External static pressure
High
Pa
150
150
150
150
150
Dimension
HxWxD
mm
283 x 975 x 1 400
408 x 1 180 x 1 720
408 x 1 580 x 1 720
408 x 1 980 x 1 720
408 x 1 980 x 1 720
Piping diameter
Liquid
Inch (mm)
1/4 (6,35)
3/8 (9,52)
3/8 (9,52)
3/8 (9,52)
3/8 (9,52)
Gas
Inch (mm)
1/2 (12,70)
5/8 (15,88)
5/8 (15,88)
5/8 (15,88)
5/8 (15,88)
1) Data refers to the following conditions (UNI EN 13141-7): nominal air flow, external air 5 °C with 72% r. / expelled air 25 °C with 28% r. * Image is for PAW-HRPT40.
Accessories
Accessories
CZ-RTC6W
CONEX wired remote controller (non-wireless), white
PAW-RE2C4-MOD-WH Room controller for hotel rooms, white
CZ-RTC6WBL
CONEX wired remote controller with Bluetooth®, white
PAW-RE2C4-MOD-BK
Room controller for hotel rooms, black
CZ-RTC6
CONEX wired remote controller (non-wireless), black
PAW-RE2D4-WH
Display control for hotel rooms, white
CZ-RTC6BL
CONEX wired remote controller with Bluetooth®, black
PAW-RE2D4-BK
Display control for hotel rooms, black
CZ-RTC5B
Wired remote controller with Econavi function
Interconnection to outdoor / indoor units
S-link communication line
ERV + DX
Indoor terminal units
CZ-RTC6W
Aeraulic performance
EC motors with electronic speed control ensure high
values of effective static pressure for ducting.
700
External static pressure (Pa)
Technical focus
· Dual flow ventilation with EC fan, featuring high
efficiency heat recovery (>85% η)
· 5 model line-up is available with air flow rates of 500,
800, 1 200, 1 600 and 2 000 m³/h
· 2 types of polypropylene heat exchanger (high efficiency
and sensible) with counter-current flows and integrated
bypass as standard
· Automatic defrosting of the exchanger
· Low consumption and EC motors with electronic speed
control ensure high useful static pressure for circular
inlet connection to air ducts
· Wide ambient temperature range up to +50 ° C and down
to -15 °C
· Modbus connection available
600
500
400
300
HRPT200
200
HRPT120
100
HRPT40
HRPT80
HRPT160
0
AUTOMATIC FAN
100
HUMIDITY CONTROL
DRY
AUTOMATIC
RESTART
BUILT-IN
DRAIN PUMP
PANASONIC
AC SMART CLOUD
BMS
CONNECTIVITY
0
500
1000
Air flow (m³/h)
1500
2000