UK RAC GEN 24 Interactive - Flipbook - Page 32
R32
GENERAL INDEX
Low static pressure hide-away · R32
· Duct type can be controlled by KNX and Modbus
· Eco mode for 20% energy saving
· Extremely compact indoor units without losing static pressure
(only 200 mm high)
· Weekly timer, 42 settings per week
· Easy check mode for failure detection
· Drain pump included
Optional
wireless
control kit.
CZ-RL511D
MORE DUCT TYPE SOLUTIONS IN PACi SECTION
Kit
KIT-Z25-UD3
KIT-Z35-UD3
KIT-Z50-UD3
KIT-Z60-UD3
Cooling capacity
Nominal (Min - Max)
kW
2,50 (0,85 - 3,20)
3,50 (0,85 - 4,00)
5,10 (0,90 - 5,70)
6,00 (0,90 - 6,50)
EER 1)
Nominal (Min - Max)
W/W
4,31 (3,54 - 3,76)
3,85 (3,54 - 3,36)
3,27 (3,53 - 3,20)
2,94 (3,53 - 2,83)
5,90 A+
5,80 A+
5,90 A+
5,60 A+
kW
2,50
3,50
5,10
6,00
kW
0,58 (0,24 - 0,85)
0,91 (0,24 - 1,19)
1,56 (0,26 - 1,78)
2,04 (0,26 - 2,30)
SEER 2)
Pdesign (cooling)
Input power
Nominal (Min - Max)
Annual energy consumption 3)
Heating capacity
kWh/a
Nominal (Min - Max)
kW
Nominal (Min - Max)
W/W
Heating capacity at -7 °C
kW
COP 1)
SCOP 2)
Pdesign at -10 °C
Input power
Nominal (Min - Max)
Annual energy consumption 3)
2,60
3,00
4,50
5,10
4,00 (3,70 - 3,68)
3,82 (3,70 - 3,59)
3,35 (3,46 - 3,27)
3,24 (3,46 - 3,08)
4,10 A+
4,10 A+
4,10 A+
2,80
4,00
4,60
kW
0,80 (0,23 - 1,25)
1,10 (0,23 - 1,42)
1,82 (0,26 - 2,20)
2,16 (0,26 - 2,60)
kWh/a
Min - Max
Pa
Cool / Heat
m³/min
Cool (Hi / Lo / Q-Lo)
dB(A)
Heat (Hi / Lo / Q-Lo)
dB(A)
HxWxD
mm
L/h
Net weight
375
7,00 (0,90 - 8,00)
2,60
Air flow
Dimension
303
6,10 (0,90 - 7,20)
4,20 A+
External static pressure 4)
Sound pressure 5)
211
4,20 (0,85 - 5,10)
kW
Indoor unit
Moisture removal volume
148
3,20 (0,85 - 4,60)
kg
Outdoor unit
867
956
1 366
1 571
CS-Z25UD3EAW
CS-Z35UD3EAW
CS-Z50UD3EAW
CS-Z60UD3EAW
15 - 45
15 - 45
15 - 50
15 - 50
10,5 / 10,5
11,2 / 11,2
15,3 / 15,3
15,7 / 15,7
1,5
2,0
2,8
3,3
33 / 27 / 24
33 / 27 / 24
39 / 29 / 26
41 / 30 / 27
35 / 27 / 24
35 / 27 / 24
39 / 30 / 27
41 / 32 / 29
200 x 750 x 640
200 x 750 x 640
200 x 750 x 640
200 x 750 x 640
19
19
19
19
CU-Z25UBEA
CU-Z35UBEA
CU-Z50UBEA
CU-Z60UBEA
230
Power supply
V
230
230
230
Recommended fuse
A
16
16
16
—
Connection indoor / outdoor
mm²
4x1,5 ~ 2,5
4x1,5 ~ 2,5
4x1,5 ~ 2,5
—
28,7 / 27,2
34,3 / 33,5
39,7 / 38,6
42,6 / 41,5
46 / 47
48 / 48
48 / 48
49 / 50
542 x 780 x 289
619 x 824 x 299
695 x 875 x 320
695 x 875 x 320
Air flow
Cool / Heat
m³/min
Sound pressure 5)
Cool / Heat (Hi)
dB(A)
Dimension 6)
HxWxD
mm
33
35
43
43
Liquid
Inch (mm)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
Gas
Inch (mm)
Net weight
kg
Piping diameter
3/8 (9,52)
3/8 (9,52)
1/2 (12,70)
1/2 (12,70)
Pipe length range
m
3 ~ 20
3 ~ 20
3 ~ 30
3 ~ 30
Elevation difference (in / out)
m
15
15
20
20
Pre-charged pipe length
m
7,5
7,5
7,5
7,5
Additional gas amount
g/m
Refrigerant (R32) / CO2 Eq.
kg / T
Operating range
10
10
15
15
0,88 / 0,594
0,93 / 0,628
1,13 / 0,763
1,13 / 0,763
Cool Min ~ Max
°C
-10 ~ +43
-10 ~ +43
-10 ~ +43
-10 ~ +43
Heat Min ~ Max
°C
-15 ~ +24
-15 ~ +24
-15 ~ +24
-15 ~ +24
1) EER and COP calculation is based in accordance to EN14511. 2) Energy Label Scale from A+++ to D. 3) The annual energy consumption is calculated in accordance to EU/626/2011. 4) The specification listed on the
table indicates values under the condition of 25 Pa (2,5 mmAq) which are applied for factory default setting. Change switch on PCB from Hi to S-Hi to have more than 6,0 mmAq. 5) The sound pressure of the indoor
unit shows the value measured of a position of 1,5 m below the unit with 1 m duct on the suction side and 2 m duct on the discharge side. For outdoor unit 1 m in front and 1 m in rear side of main body. The sound
pressure is measured in accordance with JIS C 9612. 6) Add 100 mm for indoor unit or 70 mm for outdoor unit for piping port.
Accessories
Accessories
Wi-Fi adapter for smart control via Panasonic Comfort
Cloud App
CZ-TACG1
R32
A+
5,90 SEER
A+
4,20 SCOP
-15 °C
COOLING MODE
HEATING MODE
RAC interface adapter for integration into S-Link
CZ-RL511D
Optional wireless control kit
R22
R410A
R2 ROTARY
COMPRESSOR
SEER and SCOP: For KIT-Z25-UD3. INTERNET CONTROL: Optional.
32
-10 °C
CZ-CAPRA1
STATIC PRESSURE
UP TO 7 mmAq
FILTER INCLUDED
R32
R22 / R410A
RENEWAL
INTEGRATION
TO S-LINK
OPTIONAL WI-FI
BMS
CONNECTIVITY