UK CLOSE CONTROL GEN 24 - Flipbook - Page 11
CLOSE CONTROL / VERTICALCHILLERS
DX UNITS
CLOSE CONTROL / VERTICAL DX INDEX
Technical features
Size
1 200
1 900
2 450
3 250
4 650
6 450
T-X1200.AR
T-X1900.AR
T-X2450.AR
T-X3250.AR
T-X4650.AR
T-X6450.AR
W
12 300
16 200
19 800
29 000
38 900
55 000
BTU/hr
42 000
55 300
67 600
99 000
137 000
189 200
T-XAR - air cooled models
Cooling capacity 1)
Nominal
Nominal treated air
m³/h
2 000
3 200
4 500
5 800
9 000
12 000
Min / Max treated air
m³/h
1 500 / 2 500
2 500 / 3 800
3 600 / 5 400
4 600 / 7 000
7 200 / 10 800
9 500 / 14 500
m³/h
180
285
420
500
1 300
1 650
Static pressure 2)
Standard unit
daPa
0 / 13
0 / 21
0 / 20
0 / 25
0 / 23
0 / 29
Sound pressure - indoor unit 3)
Normal speed
dB(A)
51
56
59
65
61
69
Voltage
V
Air flow
Nominal fresh air (with accessory)
Electrical data
Power supply
Phase
Frequency
Voltage range
V
Total input power 1)
Input power ventilation
Hz
Min / Max - standard unit
400
400
400
400
400
400
Three phase
Three phase
Three phase
Three phase
Three phase
Three phase
50
50
50
50
50
50
360 / 440
360 / 440
360 / 440
360 / 440
360 / 440
360 / 440
W
4 808
8 076
8 900
12 630
16 950
24 000
W
260 / 510
380 / 580
500 / 1 100
700 / 1 800
1 600 / 2 400
3 100 / 4 600
mm
1540
1 735
1 840
1 830
1 970
1 970
mm
430
500
600
600
790
790
mm
890
1 000
1 300
1 530
1 715
1 980
Dimensions
Dimensions
HxWxL
UC - outdoor condensing unit (accessory)
Compatible with / number of necessary outdoor unit(s)
UC34
UC54
UC74
UC104
X1200.AR / 1
X1900.AR / 1
X2450.AR / 1
X4650.AR / 2
X3250.AR / 1
X6450.AR / 2
Air flow
m³/h
8 600
7 600
8 550
14 000
Input power
W
530
611
611
1 222
Sound pressure 4)
dB(A)
52
53
56
56
mm
840
840
840
840
mm
825
825
885
885
mm
885
885
1 141
1 546
Dimensions
Dimensions
HxWxL
1) International standard ISO 51.51 conditions. 27 °C/19 °C (WB) - outside air : 35 °C/24 °C (WB). Wasted water: inlet +15 °C - recycled water inlet/outlet: 30 °C/35 °C. 2) Pressure in air flow range at nominal
voltage, without accessories. 3) Total sound pressure dB(A) (4 m) under nominal conditions in a room of 1 000 m³ (reverberation 0,83 s). 4) Total sound pressure dB(A) (4 m) under nominal conditions in free field
on reflecting surface.
Accessories and options
Accessories and options
Air distribution duct frame
ON / OFF switch and room thermostat
Electric heaters
Pipe link 10 m - 1 circuit
Fresh air intake
Remote fault reporting
Front air distribution plenum
Set of female valves (mandatory)
High ventilation (provided as standard for sizes 1200 and 1900)
Total rear intake duct frame
Hot water coil
UC - outdoor condensing unit
SCROLL
COMPRESSOR
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
11