UK BIGRAC GEN 24 - Flipbook - Page 49
R32
COMMERCIAL INDEX
COMMERCIAL
COMPATIBLE WITH ALL PANASONIC CONNECTIVITY SOLUTIONS. FOR
DETAILED INFORMATION GO TO THE CONTROL SYSTEMS SECTION
CZ-RTC5B
Optional:
CONEX wired
remote
controller,
white.
CZ-RTC6W/
BL/BLW
CONEX wired
remote
controller,
black.
CZ-RTC6/BL/
BLW
Infrared
remote
controller.
CZ-RWS3 +
CZ-RWRC3
Econavi
sensor.
CZ-CENSC1
Three phase
Kit
10,0 kW
12,5 kW
14,0 kW
KIT-100PF3Z8
KIT-125PF3Z8
KIT-140PF3Z8
Remote controller
CZ-RTC5B
CZ-RTC5B
CZ-RTC5B
9,5 (3,0 - 11,4)
12,1 (3,2 - 13,5)
13,4 (3,3 - 15,0)
3,57 (2,36 - 5,08)
3,40 (2,76 - 5,08)
3,16 (2,56 - 5,08)
6,5 A++
256,2%
251,4%
kW
9,5
12,1
13,4
kW
2,66 (0,59 - 4,84)
3,56 (0,63 - 4,90)
4,24 (0,65 - 5,86)
Cooling capacity
Nominal (Min - Max)
kW
EER 1)
Nominal (Min - Max)
W/W
SEER / ηs,c 2)
Pdesign
Input power
Nominal (Min - Max)
Annual energy consumption 3)
kWh/a
508
—
—
9,5 (3,0 - 13,5)
12,1 (3,3 - 15,0)
13,4 (3,4 - 16,0)
4,09 (3,00 - 5,08)
3,56 (3,16 - 5,24)
3,76 (3,03 - 5,23)
3,9 A
142,6%
140,6%
kW
7,8
9,3
9,5
kW
2,32 (0,59 - 4,50)
3,40 (0,63 - 4,74)
3,56 (0,65 - 5,28)
Heating capacity
Nominal (Min - Max)
kW
COP 1)
Nominal (Min - Max)
W/W
SCOP / ηs,h 2)
Pdesign at -10 °C
Input power
Nominal (Min - Max)
Annual energy consumption 3)
kWh/a
Indoor unit
External static pressure 4)
Nominal (Min - Max)
Pa
Air flow
Hi / Med / Lo
m³/min
Moisture removal volume
2 795
—
—
S-1014PF3E
S-1014PF3E
S-1014PF3E
40 (10 - 150)
50 (10 - 150)
50 (10 - 150)
32,0 / 26,0 / 21,0
34,0 / 29,0 / 23,0
36,0 / 32,0 / 25,0
L/h
Sound pressure 5)
Hi / Med / Lo
dB(A)
Sound power
Hi / Med / Lo
dB(A)
Dimension
HxWxD
mm
Net weight
4,1
4,9
35 / 31 / 27
39 / 35 / 29
56 / 52 / 48
58 / 54 / 50
62 / 58 / 52
250 x 1 400 x 730
250 x 1 400 x 730
250 x 1 400 x 730
kg
nanoe X Generator
Outdoor unit
3,2
33 / 29 / 25
39
39
39
Mark 2
Mark 2
Mark 2
U-100PZ3E8
U-125PZ3E8
U-140PZ3E8
V
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
Cool
A
4,45 - 4,20 - 4,05
5,75 - 5,45 - 5,25
6,85 - 6,50 - 6,30
Heat
A
3,85 - 3,70 - 3,55
5,50 - 5,20 - 5,05
5,75 - 5,45 - 5,25
Air flow
Cool / Heat
m³/min
73,0 / 73,0
82,0 / 80,0
84,0 / 82,0
Sound pressure
Cool / Heat (Hi)
dB(A)
52 / 52
55 / 55
56 / 56
Sound power
Cool / Heat (Hi)
dB(A)
70 / 70
73 / 73
74 / 74
Dimension
HxWxD
996 x 980 x 370
996 x 980 x 370
996 x 980 x 370
83
87
87
Inch (mm)
3/8 (9,52)
3/8 (9,52)
3/8 (9,52)
Inch (mm)
5/8 (15,88)
Power supply
Current
mm
Net weight
kg
Liquid
Piping diameter
5/8 (15,88)
5/8 (15,88)
Pipe length range
Gas
m
5 ~ 50
5 ~ 50
5 ~ 50
Elevation difference (in / out) 8)
m
15 / 30
15 / 30
15 / 30
Pre-charged pipe length
m
30
30
30
Additional gas amount
g/m
45
45
45
Refrigerant (R32) / CO2 Eq.
kg / T
2,40 / 1,62
2,80 / 1,89
2,80 / 1,89
Operating range
Cool Min ~ Max
°C
-10 ~ +43
-10 ~ +43
-10 ~ +43
Heat Min ~ Max
°C
-15 ~ +24
-15 ~ +24
-15 ~ +24
1) EER and COP calculation is based in accordance to EN14511. 2) For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the ηs,c / ηs,h values is
calculated based on EN 14825. 3) Factory setting. 4) Medium external static pressure setting from factory. 5) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The
sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 6) Connect the liquid socket tube (Ø6,35-Ø9,52) to the liquid tubing side indoor unit. 7) Connect the gas socket tube
(Ø12,70-Ø15,88) to the gas tubing side indoor unit. 8) Outdoor unit located lower / outdoor unit located higher. * Recommended fuse for the indoor 3 A. ** Above values are in the case of standard
installation(horizontal installation in the celling, rear side air intake) and nanoe™ X OFF.
Accessories
Accessories
CZ-RTC6W
CONEX wired remote controller (non-wireless), white
CZ-RTC6WBL
CONEX wired remote controller with Bluetooth®, white
PAW-WTRAY
Tray for condenser water compatible with outdoor elevation
platform
CZ-RTC6WBLW
CONEX wired remote controller with Wi-Fi and Bluetooth®, white
PAW-GRDBSE20
Outdoor base ground support for noise and vibration absorption
CZ-RTC6
CONEX wired remote controller (non-wireless), black
PAW-GRDSTD40
Outdoor elevation platform 400 x 900 x 400 mm
CZ-RTC6BL
CONEX wired remote controller with Bluetooth®, black
CZ-CENSC1
Econavi energy saving sensor
CZ-RTC6BLW
CONEX wired remote controller with Wi-Fi and Bluetooth®, black
CZ-56DAF2
Air outlet plenum for S-3650PF3E
CZ-RTC5B
Wired remote controller with Econavi function and datanavi
CZ-90DAF2
Air outlet plenum for S-6071PF3E
CZ-RWS3 + CZ-RWRC3 Infrared remote controller and receiver
CZ-160DAF2
Air outlet plenum for S-1014PF3E
CZ-CAPWFC1
Commercial Wi-Fi Adaptor
PAW-APF800F
NEW BION air pollutant filter for S-3650PF3E
PAW-PACR4
Interface to run up to 4 indoor unit groups on backup and
alternative run
PAW-APF1000F
NEW BION air pollutant filter for S-6071PF3E
PAW-APF1400F
NEW BION air pollutant filter for S-1014PF3E
R32
A++
A+
6,6 SEER
4,4 SCOP
-10 °C
-15 °C
COOLING MODE
HEATING MODE
R22
R410A
22 dB(A)
DC FAN
FILTER INCLUDED
R32
R22 / R410A
RENEWAL
OPTIONAL WI-FI
BMS
CONNECTIVITY
SEER: For S-1014PF3E + U-100PZ3E5. SCOP: For S-6071PF3E + U-60PZ3E5A. SUPER QUIET: For S-3650PF3E + U-36PZ3E5. INTERNET CONTROL: Optional.
Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
49