UK BIGRAC GEN 24 - Flipbook - Page 43
R32
COMMERCIAL INDEX
COMMERCIAL
COMPATIBLE WITH ALL PANASONIC CONNECTIVITY SOLUTIONS. FOR
DETAILED INFORMATION GO TO THE CONTROL SYSTEMS SECTION
CZ-RTC5B
Optional:
CONEX wired
remote
controller,
white.
CZ-RTC6W/
BL/BLW
CONEX wired
remote
controller,
black.
CZ-RTC6/BL/
BLW
Infrared remote
controller.
CZ-RWS3 +
CZ-RWRT3
Econavi
sensor.
CZ-CENSC1
Three phase
Kit
7,1 kW
10,0 kW
12,5 kW
14,0 kW
KIT-71PT3ZH48
KIT-100PT3ZH48
KIT-125PT3ZH48
KIT-140PT3ZH48
Remote controller
CZ-RTC5B
CZ-RTC5B
CZ-RTC5B
CZ-RTC5B
6,8 (2,2 - 9,0)
9,5 (3,1 - 12,5)
12,1 (3,2 - 14,0)
13,4 (3,3 - 16,0)
3,91 (2,69 - 5,79)
4,06 (3,29 - 5,34)
3,46 (3,01 - 5,33)
3,21 (2,67 - 5,32)
7,2 A++
7,2 A++
277,3%
262,4%
kW
6,8
9,5
12,1
13,4
kW
1,74 (0,38 - 3,35)
2,34 (0,58 - 3,80)
3,50 (0,60 - 4,65)
4,17 (0,66 - 6,00)
Cooling capacity
Nominal (Min - Max)
kW
EER 1)
Nominal (Min - Max)
W/W
SEER / ηs,c 2)
Pdesign
Input power
Nominal (Min - Max)
Annual energy consumption 3)
kWh/a
331
462
—
—
8,0 (2,0 - 9,0)
11,2 (3,1 - 14,0)
14,0 (3,2 - 16,0)
16,0 (3,3 - 18,0)
3,96 (3,16 - 5,56)
4,00 (3,54 - 5,54)
3,78 (3,20 - 5,52)
3,38 (3,10 - 5,50)
4,7 A++
4,5 A+
175,6%
169,3%
kW
4,7
7,8
9,5
10,2
kW
2,02 (0,36 - 2,85)
2,80 (0,56 - 3,95)
3,70 (0,58 - 5,00)
4,74 (0,60 - 5,80)
Heating capacity
Nominal (Min - Max)
kW
COP 1)
Nominal (Min - Max)
W/W
SCOP / ηs,h 2)
Pdesign at -10 °C
Input power
Nominal (Min - Max)
Annual energy consumption 3)
kWh/a
Indoor unit
Air flow
Hi / Med / Lo
m³/min
Moisture removal volume
1 400
2 427
—
—
S-6071PT3E
S-1014PT3E
S-1014PT3E
S-1014PT3E
21,0 / 18,0 / 15,5
30,0 / 25,0 / 23,0
34,0 / 28,0 / 24,0
35,0 / 29,0 / 25,0
2,7
3,6
5,4
6,4
39 / 35 / 30
42 / 37 / 34
46 / 40 / 35
47 / 41 / 36
L/h
Sound pressure 4)
Hi / Med / Lo
dB(A)
Sound power
Hi / Med / Lo
dB(A)
Dimension
HxWxD
mm
Net weight
57 / 53 / 48
60 / 55 / 52
64 / 58 / 53
65 / 59 / 54
235 x 1 275 x 690
235 x 1 590 x 690
235 x 1 590 x 690
235 x 1 590 x 690
kg
nanoe X Generator
Outdoor unit
40
40
40
Mark 2
Mark 2
Mark 2
U-140PZH4E8
U-71PZH4E8
U-100PZH4E8
U-125PZH4E8
V
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
Cool
A
2,95 - 2,80 - 2,70
3,60 - 3,40 - 3,25
5,45 - 5,15 - 5,00
6,15 - 5,85 - 5,65
3,15 - 3,00 - 2,90
3,75 - 3,55 - 3,40
5,10 - 4,80 - 4,65
6,20 - 5,90 - 5,65
62,0 / 66,0
76,0 / 70,0
86,0 / 78,0
89,0 / 83,0
Power supply
Current
34
Mark 2
Heat
A
Air flow
Cool / Heat
m³/min
Sound pressure
Cool / Heat (Hi)
dB(A)
48 / 50
52 / 52
55 / 55
56 / 56
Sound power
Cool / Heat (Hi)
dB(A)
65 / 67
69 / 69
73 / 73
74 / 74
Dimension
HxWxD
996 x 980 x 370
996 x 980 x 370
996 x 980 x 370
996 x 980 x 370
66
82
84
84
mm
Net weight
kg
Piping diameter
Liquid
Inch (mm)
3/8 (9,52)
3/8 (9,52)
3/8 (9,52)
3/8 (9,52)
Gas
Inch (mm)
5/8 (15,88)
5/8 (15,88)
5/8 (15,88)
5/8 (15,88)
Pipe length range
m
5 ~ 60
5 ~ 100
5 ~ 100
5 ~ 100
Elevation difference (in / out) 7)
m
15 / 30
15 / 30
15 / 30
15 / 30
Pre-charged pipe length
m
30
30
30
30
Additional gas amount
g/m
30
40
40
40
Refrigerant (R32) / CO2 Eq.
Operating range
kg / T
1,95 / 1,32
2,70 / 1,82
3,00 / 2,03
3,00 / 2,03
Cool Min ~ Max
°C
-15 ~ +52
-20 8) ~ +52
-20 8) ~ +52
-20 8) ~ +52
Heat Min ~ Max
°C
-20 ~ +24
-20 ~ +24
-20 ~ +24
-20 ~ +24
1) EER and COP calculation is based in accordance to EN14511. 2) For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the ηs,c / ηs,h values is
calculated based on EN 14825. 3) Factory setting. 4) The sound pressure of the units shows the value measured of the position 1 m in front of the main body and 1 m below the unit. The sound pressure is
measured in accordance with Eurovent 6/C/006-97 specification. 5) Connect the liquid socket tube (Ø6,35-Ø9,52) to the liquid tubing side indoor unit. 6) Connect the gas socket tube (Ø12,70-Ø15,88) to the gas
tubing side indoor unit. 7) Outdoor unit located lower / outdoor unit located higher. 8) Pipe length up to 30 m. * Recommended fuse for the indoor 3 A. ** Above values are in the case of nanoe™ X OFF.
Accessories
Accessories
CZ-RTC6W
CONEX wired remote controller (non-wireless), white
CZ-RTC6WBL
CONEX wired remote controller with Bluetooth®, white
CZ-RTC6WBLW
CONEX wired remote controller with Wi-Fi and Bluetooth®, white
CZ-RTC6
CONEX wired remote controller (non-wireless), black
CZ-RTC6BL
CONEX wired remote controller with Bluetooth®, black
CZ-CAPWFC1
Commercial Wi-Fi Adaptor
PAW-PACR4
Interface to run up to 4 indoor unit groups on backup and
alternative run
PAW-WTRAY
Tray for condenser water compatible with outdoor elevation
platform
CZ-RTC6BLW
CONEX wired remote controller with Wi-Fi and Bluetooth®, black
PAW-GRDBSE20
Outdoor base ground support for noise and vibration absorption
CZ-RTC5B
Wired remote controller with Econavi function and datanavi
PAW-GRDSTD40
Outdoor elevation platform 400 x 900 x 400 mm
CZ-CENSC1
Econavi energy saving sensor
CZ-RWS3 +
CZ-RWRT3
R32
Infrared remote controller and receiver
A++
A++
7,7 SEER
4,9 SCOP
-15 °C
-20 °C
COOLING MODE
HEATING MODE
R22
R410A
R32
R22 / R410A
RENEWAL
OPTIONAL WI-FI
BMS
CONNECTIVITY
5
YEARS
COMPRESSOR
WARRANTY
SEER and SCOP: For S-3650PT3E + U-36PZH3E5. INTERNET CONTROL: Optional.
Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.