UK BIGRAC GEN 24 - Flipbook - Page 39
R32
COMMERCIAL INDEX
Standard panel.
CZ-KPU3W
Optional Econavi panel
(CZ-RTC5B is required).
CZ-KPU3AW
COMMERCIAL
COMPATIBLE WITH ALL PANASONIC CONNECTIVITY SOLUTIONS. FOR
DETAILED INFORMATION GO TO THE CONTROL SYSTEMS SECTION
CZ-RTC5B
Optional:
CONEX wired
remote
controller,
white.
CZ-RTC6W/
BL/BLW
CONEX wired
remote
controller,
black.
CZ-RTC6/BL/
BLW
Infrared
remote
controller.
CZ-RWS3 +
CZ-RWRU3W
Three phase
Kit
7,1 kW
10,0 kW
12,5 kW
14,0 kW
KIT-71PU3ZH48
KIT-100PU3ZH48
KIT-125PU3ZH48
KIT-140PU3ZH48
Remote controller
CZ-RTC5B
CZ-RTC5B
CZ-RTC5B
CZ-RTC5B
7,1 (2,2 - 9,0)
9,5 (3,1 - 12,5)
12,5 (3,2 - 14,0)
13,4 (3,3 - 16,0)
4,06 (2,69 - 5,79)
4,42 (3,42 - 5,34)
3,80 (3,08 - 5,33)
3,60 (2,74 - 5,32)
7,7 A++
7,2 A++
303,0%
286,6%
kW
7,1
9,5
12,5
13,4
kW
1,75 (0,38 - 3,35)
2,15 (0,58 - 3,65)
3,29 (0,60 - 4,55)
3,72 (0,62 - 5,85)
Cooling capacity
Nominal (Min - Max)
kW
EER 1)
Nominal (Min - Max)
W/W
SEER / ηs,c 2)
Pdesign
Input power
Nominal (Min - Max)
Annual energy consumption 3)
kWh/a
323
426
—
—
8,0 (2,0 - 9,0)
11,2 (3,1 - 14,0)
14,0 (3,2 - 16,0)
16,0 (3,3 - 18,0)
4,30 (3,16 - 5,56)
5,00 (3,64 - 5,54)
4,61 (3,37 - 5,52)
4,30 (3,27 - 5,50)
4,8 A++
4,9 A++
186,0%
181,1%
kW
5,2
8,0
9,5
10,6
kW
1,86 (0,36 - 2,85)
2,24 (0,56 - 3,85)
3,04 (0,58 - 4,75)
3,72 (0,60 - 5,50)
Heating capacity
Nominal (Min - Max)
kW
COP 1)
Nominal (Min - Max)
W/W
SCOP / ηs,h 2)
Pdesign at -10 °C
Input power
Nominal (Min - Max)
Annual energy consumption 3)
kWh/a
Indoor unit
Air flow
Hi / Med / Lo
Moisture removal volume
m³/min
1 517
2 286
—
—
S-6071PU3E
S-1014PU3E
S-1014PU3E
S-1014PU3E
22,0 / 16,0 / 13,0
36,0 / 26,0 / 18,0
37,0 / 27,0 / 19,0
38,0 / 29,0 / 20,0
2,5
1,9
4,8
4,9
37 / 31 / 28
45 / 38 / 32
46 / 39 / 33
47 / 40 / 34
L/h
Sound pressure 4)
Sound power
Dimension
Net weight
Hi / Med / Lo
dB(A)
Hi / Med / Lo
dB(A)
52 / 46 / 43
60 / 53 / 47
61 / 54 / 48
62 / 55 / 49
Indoor (H x W x D)
mm
256 x 840 x 840
319 x 840 x 840
319 x 840 x 840
319 x 840 x 840
Panel (H x W x D)
mm
33,5 x 950 x 950
33,5 x 950 x 950
33,5 x 950 x 950
33,5 x 950 x 950
Indoor / Panel
kg
20 / 5
25 / 5
25 / 5
25 / 5
Mark 1
Mark 1
Mark 1
Mark 1
U-140PZH4E8
nanoe X Generator
Outdoor unit
U-71PZH4E8
U-100PZH4E8
U-125PZH4E8
V
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
Cool
A
2,95 - 2,80 - 2,70
3,60 - 3,40 - 3,25
5,45 - 5,15 - 5,00
6,15 - 5,85 - 5,65
3,15 - 3,00 - 2,90
3,75 - 3,55 - 3,40
5,10 - 4,80 - 4,65
6,20 - 5,90 - 5,65
62,0 / 66,0
76,0 / 70,0
86,0 / 78,0
89,0 / 83,0
Power supply
Current
Heat
A
Air flow
Cool / Heat
m³/min
Sound pressure
Cool / Heat (Hi)
dB(A)
48 / 50
52 / 52
55 / 55
56 / 56
Sound power
Cool / Heat (Hi)
dB(A)
65 / 67
69 / 69
73 / 73
74 / 74
Dimension
HxWxD
996 x 980 x 370
996 x 980 x 370
996 x 980 x 370
996 x 980 x 370
66
82
84
84
Inch (mm)
3/8 (9,52)
3/8 (9,52)
3/8 (9,52)
3/8 (9,52)
Inch (mm)
Net weight
mm
kg
Liquid
Piping diameter
5/8 (15,88)
5/8 (15,88)
5/8 (15,88)
5/8 (15,88)
Pipe length range
Gas
m
5 ~ 60
5 ~ 100
5 ~ 100
5 ~ 100
Elevation difference (in / out) 7)
m
15 / 30
15 / 30
15 / 30
15 / 30
Pre-charged pipe length
m
30
30
30
30
Additional gas amount
g/m
30
40
40
40
Refrigerant (R32) / CO2 Eq.
kg / T
1,95 / 1,32
2,70 / 1,82
3,00 / 2,03
3,00 / 2,03
Cool Min ~ Max
°C
-15 ~ +52
-20 8) ~ +52
-20 8) ~ +52
-20 8) ~ +52
Heat Min ~ Max
°C
-20 ~ +24
-20 ~ +24
-20 ~ +24
-20 ~ +24
Operating range
1) EER and COP calculation is based in accordance to EN14511. 2) For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the ηs,c / ηs,h values is
calculated based on EN 14825. 3) Factory setting. 4) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The sound pressure is measured in accordance with Eurovent
6/C/006-97 specification. 5) Connect the liquid socket tube (Ø6,35-Ø9,52) to the liquid tubing side indoor unit. 6) Connect the gas socket tube (Ø12,70-Ø15,88) to the gas tubing side indoor unit. 7) Outdoor unit
located lower / outdoor unit located higher. 8) Pipe length up to 30 m. * Recommended fuse for the indoor 3 A. ** Above values are in the case of nanoe™ X OFF.
Accessories
Accessories
CZ-RTC6W
CONEX wired remote controller (non-wireless), white
CZ-CAPWFC1
Commercial Wi-Fi Adaptor
CZ-RTC6WBL
CONEX wired remote controller with Bluetooth®, white
CZ-KPU3AW
Econavi exclusive panel
CZ-RTC6WBLW
CONEX wired remote controller with Wi-Fi and Bluetooth®, white
CZ-RTC6
CONEX wired remote controller (non-wireless), black
PAW-PACR4
Interface to run up to 4 indoor unit groups on backup and
alternative run
CZ-RTC6BL
CONEX wired remote controller with Bluetooth®, black
CZ-RTC6BLW
CONEX wired remote controller with Wi-Fi and Bluetooth®, black
PAW-WTRAY
Tray for condenser water compatible with outdoor elevation
platform
CZ-RTC5B
Wired remote controller with Econavi function and datanavi
PAW-GRDBSE20
Outdoor base ground support for noise and vibration absorption
PAW-GRDSTD40
Outdoor elevation platform 400 x 900 x 400 mm
CZ-RWS3 +
CZ-RWRU3W
R32
Infrared remote controller and receiver
A+++
A+++
8,9 SEER
5,1 SCOP
28%
CZ-FDU3+CZ-ATU2 Fresh air-intake kit
-15 °C
-20 °C
COOLING MODE
HEATING MODE
R22
R410A
DC FAN
R32
R22 / R410A
RENEWAL
OPTIONAL WI-FI
BMS
CONNECTIVITY
SEER and SCOP: For S-3650PU3E + U-36PZH3E5. ECONAVI and INTERNET CONTROL: Optional.
Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
39