UK BIGRAC GEN 24 - Flipbook - Page 37
R32
COMMERCIAL INDEX
Panel.
CZ-KPY4
COMMERCIAL
COMPATIBLE WITH ALL PANASONIC CONNECTIVITY SOLUTIONS. FOR
DETAILED INFORMATION GO TO THE CONTROL SYSTEMS SECTION
CZ-RTC5B
Optional:
CONEX wired
remote
controller,
white.
CZ-RTC6W/
BL/BLW
CONEX wired
remote
controller,
black.
CZ-RTC6/BL/
BLW
Standard
Infrared
remote
controller.
CZ-RWS3 +
CZ-RWRY3
Econavi
sensor.
CZ-CENSC1
Single phase
Kit
2,5 kW
3,6 kW
5,0 kW
6,0 kW
KIT-25PY3Z5
KIT-36PY3Z5
KIT-50PY3Z5
KIT-60PY3Z5
Remote controller
CZ-RTC5B
CZ-RTC5B
CZ-RTC5B
CZ-RTC5B
2,5 (1,5 - 3,9)
3,6 (1,5 - 4,0)
5,0 (1,5 - 5,6)
6,0 (2,0 - 7,0)
4,46 (3,55 - 5,88)
3,96 (3,57 - 5,88)
3,50 (3,03 - 6,25)
3,39 (2,77 - 6,90)
6,5 A++
6,7 A++
7,3 A++
6,8 A++
kW
2,5
3,6
5,0
6,0
kW
0,56 (0,26 - 1,10)
0,91 (0,26 - 1,12)
1,43 (0,24 - 1,85)
1,77 (0,29 - 2,53)
Cooling capacity
Nominal (Min - Max)
kW
EER 1)
Nominal (Min - Max)
W/W
SEER 2)
Pdesign
Input power
Nominal (Min - Max)
Annual energy consumption 3)
kWh/a
134
188
238
3,05
3,2 (1,5 - 4,6)
3,6 (1,5 - 4,6)
5,0 (1,5 - 6,4)
6,0 (1,8 - 7,0)
4,44 (3,41 - 6,52)
4,29 (3,38 - 6,52)
3,94 (2,91 - 7,50)
3,61 (2,86 - 7,60)
4,6 A++
4,3 A+
4,4 A+
4,2 A+
kW
2,8
2,8
4,0
4,6
kW
0,72 (0,23 - 1,35)
0,84 (0,23 - 1,36)
1,27 (0,20 - 2,20)
1,66 (0,24 - 2,45)
Heating capacity
Nominal (Min - Max)
kW
COP 1)
Nominal (Min - Max)
W/W
SCOP 2)
Pdesign at -10 °C
Input power
Nominal (Min - Max)
Annual energy consumption 3)
kWh/a
850
912
1 264
1 500
S-25PY3E
S-36PY3E
S-50PY3E
S-60PY3E
8,5 / 7,0 / 6,0
9,5 / 7,0 / 6,0
12,0 / 9,5 / 6,5
14,0 / 10,5 / 8,0
0,7
1,5
2,3
2,8
31 / 28 / 25
34 / 30 / 25
39 / 34 / 27
43 / 37 / 31
Indoor unit
Air flow
Hi / Med / Lo
Moisture removal volume
m³/min
L/h
Sound pressure 4)
Sound power
Dimension
Net weight
Hi / Med / Lo
dB(A)
Hi / Med / Lo
dB(A)
46 / 43 / 40
49 / 45 / 40
54 / 49 / 42
58 / 52 / 46
Indoor (H x W x D)
mm
243 x 575 x 575
243 x 575 x 575
243 x 575 x 575
243 x 575 x 575
Panel (H x W x D)
mm
30 x 625 x 625
30 x 625 x 625
30 x 625 x 625
30 x 625 x 625
Indoor / Panel
kg
15 / 2,8
15 / 2,8
15 / 2,8
15 / 2,8
Mark 2
Mark 2
Mark 2
Mark 2
nanoe X Generator
Outdoor unit
U-25PZ3E5
U-36PZ3E5
U-50PZ3E5
U-60PZ3E5A
V
220 - 230 - 240
220 - 230 - 240
220 - 230 - 240
220 - 230 - 240
Cool
A
2,65 - 2,55 - 2,45
4,20 - 4,05 - 3,85
6,65 - 6,35 - 6,10
8,20 - 7,85 - 7,55
Heat
A
3,40 - 3,25 - 3,10
3,95 - 3,75 - 3,60
5,695 - 5,70 - 5,45
7,70 - 7,35 - 7,05
42,6 / 41,5
Power supply
Current
Air flow
Cool / Heat
m³/min
33,6 / 34,0
32,6 / 34,0
32,7 / 31,9
Sound pressure
Cool / Heat (Hi)
dB(A)
46 / 47
46 / 47
46 / 48
47 / 48
Sound power
Cool / Heat (Hi)
dB(A)
64 / 66
64 / 66
64 / 64
64 / 65
Dimension
HxWxD
619 x 824 x 299
619 x 824 x 299
619 x 824 x 299
695 x 875 x 320
32
32
35
46
Inch (mm)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35) 5)
Inch (mm)
1/2 (12,70) 6)
Net weight
mm
kg
Liquid
Piping diameter
1/2 (12,70)
1/2 (12,70)
1/2 (12,70)
Pipe length range
Gas
m
3 ~ 15
3 ~ 15
3 ~ 20
3 ~ 40
Elevation difference (in / out) 7)
m
15 / 15
15 / 15
15 / 15
15 / 30
Pre-charged pipe length
m
7,5
7,5
7,5
30
Additional gas amount
g/m
10
10
15
15
1,15 / 0,78
Refrigerant (R32) / CO2 Eq.
Operating range
kg / T
0,87 / 0,59
0,87 / 0,59
1,14 / 0,77
Cool Min ~ Max
°C
-10 ~ +43
-10 ~ +43
-10 ~ +43
-10 ~ +43
Heat Min ~ Max
°C
-15 ~ +24
-15 ~ +24
-15 ~ +24
-15 ~ +24
1) EER and COP calculation is based in accordance to EN14511. 2) For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the ηs,c / ηs,h values is
calculated based on EN 14825. 3) Factory setting. 4) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The sound pressure is measured in accordance with Eurovent
6/C/006-97 specification. 5) Connect the liquid socket tube (Ø6,35-Ø9,52) to the liquid tubing side indoor unit. 6) Connect the gas socket tube (Ø12,70-Ø15,88) to the gas tubing side indoor unit. 7) Outdoor unit located
lower / outdoor unit located higher. * Recommended fuse for the indoor 3 A. ** Above values are in the case of nanoe™ X OFF.
Accessories
Accessories
CZ-RTC6W
CONEX wired remote controller (non-wireless), white
CZ-RTC6WBL
CONEX wired remote controller with Bluetooth®, white
CZ-RTC6WBLW
CONEX wired remote controller with Wi-Fi and Bluetooth®, white
CZ-RTC6
CONEX wired remote controller (non-wireless), black
CZ-RTC6BL
CONEX wired remote controller with Bluetooth®, black
CZ-CAPWFC1
Commercial Wi-Fi Adaptor
PAW-PACR4
Interface to run up to 4 indoor unit groups on backup and
alternative run
PAW-WTRAY
Tray for condenser water compatible with outdoor elevation
platform
CZ-RTC6BLW
CONEX wired remote controller with Wi-Fi and Bluetooth®, black
PAW-GRDBSE20
Outdoor base ground support for noise and vibration absorption
CZ-RTC5B
Wired remote controller with Econavi function and datanavi
PAW-GRDSTD40
Outdoor elevation platform 400 x 900 x 400 mm
CZ-CENSC1
Econavi energy saving sensor
CZ-RWS3 +
CZ-RWRY3
R32
Infrared remote controller and receiver
A++
A++
7,3 SEER
4,6 SCOP
28%
-10 °C
-15 °C
COOLING MODE
HEATING MODE
R22
R410A
DC FAN
R32
R22 / R410A
RENEWAL
OPTIONAL WI-FI
BMS
CONNECTIVITY
SEER: For S-50PY3E + U-50PZ3E5. SCOP: For S-25PY3E + U-25PZ3E5. ECONAVI and INTERNET CONTROL: Optional.
Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
37