UK BIGRAC GEN 24 - Flipbook - Page 34
R32
GENERAL INDEX
PACi NX Series Standard wall-mounted - PK3 · R32
The wall-mounted units with stylish matt color can be offered for many
applications such as studios, gyms, high ceiling areas and even computer
server rooms.
The compact design and flat face ensure discreet installation, even in a small
space.
nanoe™ X as a standard.
Single phase
Kit
Remote controller
3,6 kW
5,0 kW
6,0 kW
7,1 kW
10,0 kW
KIT-36PK3Z5
KIT-50PK3Z5
KIT-60PK3Z5
KIT-71PK3Z5
KIT-100PK3Z5
CZ-RTC5B
CZ-RTC5B
CZ-RTC5B
CZ-RTC5B
CZ-RTC5B
3,6 (1,5 - 4,0)
5,0 (1,5 - 5,6)
6,1 (2,0 - 7,1)
7,1 (2,6 - 7,7)
9,0 (3,0 - 9,7)
4,14 (3,74 - 5,88)
3,52 (3,03 - 6,25)
3,67 (3,01 - 6,90)
3,16 (2,77 - 5,00)
3,47 (3,13 - 5,36)
7,6 A++
7,4 A++
7,0 A++
5,8 A+
6,5 A++
kW
3,6
5,0
6,1
7,1
9,0
Nominal (Min - Max)
kW
0,87 (0,26 - 1,07)
1,42 (0,24 - 1,85)
1,66 (0,29 - 2,36)
2,25 (0,52 - 2,78)
2,59 (0,56 - 3,10)
Heating capacity
Nominal (Min - Max)
kW
COP 1)
Nominal (Min - Max)
W/W
Cooling capacity
Nominal (Min - Max)
kW
EER 1)
Nominal (Min - Max)
W/W
SEER 2)
Pdesign
Input power
Annual energy consumption 3)
kWh/a
166
237
3,05
429
485
3,6 (1,5 - 4,6)
5,0 (1,5 - 6,4)
6,1 (1,8 - 7,0)
7,1 (2,1 - 8,1)
9,0 (3,0 - 10,5)
4,62 (4,11 - 6,52)
4,20 (3,17 - 7,50)
4,39 (3,18 - 7,50)
4,23 (3,38 - 6,36)
3,93 (3,56 - 5,36)
4,5 A+
4,4 A+
4,7 A++
4,4 A+
3,9 A
kW
2,8
4,0
4,6
5,2
9,0
kW
0,78 (0,23 - 1,12)
1,19 (0,20 - 2,02)
1,39 (0,24 - 2,20)
1,68 (0,33 - 2,40)
2,29 (0,56 - 2,95)
SCOP 2)
Pdesign at -10 °C
Input power
Nominal (Min - Max)
Annual energy consumption 3)
kWh/a
Indoor unit
Air flow
Hi / Med / Lo
Moisture removal volume
m³/min
L/h
Sound pressure 4)
Hi / Med / Lo
Sound power
Hi / Med / Lo
dB(A)
Dimension
HxWxD
mm
Net weight
dB(A)
kg
nanoe X Generator
Outdoor unit
872
1 273
1 370
1 653
3 231
S-3650PK3E
S-3650PK3E
S-6010PK3E
S-6010PK3E
S-6010PK3E
13,0 / 11,0 / 9,0
16,0 / 13,5 / 11,0
20,0 / 17,5 / 14,5
20,0 / 17,5 / 14,5
22,0 / 18,5 / 15,0
0,9
1,8
2,0
3,0
4,3
35 / 31 / 27
40 / 36 / 32
47 / 44 / 40
47 / 44 / 40
49 / 45 / 41
51 / 47 / 43
56 / 52 / 48
63 / 60 / 56
63 / 60 / 56
65 / 61 / 57
302 x 1 120 x 236
302 x 1 120 x 236
302 x 1 120 x 236
302 x 1 120 x 236
302 x 1 120 x 236
13
13
14
14
14
Mark 2
Mark 2
Mark 2
Mark 2
Mark 2
U-36PZ3E5
U-50PZ3E5
U-60PZ3E5A
U-71PZ3E5A
U-100PZ3E5
V
220 - 230 - 240
220 - 230 - 240
220 - 230 - 240
220 - 230 - 240
220 - 230 - 240
Cool
A
4,05 - 3,85 - 3,70
6,60 - 6,30 - 6,05
7,70 - 7,35 - 7,05
10,4 - 10,00 - 9,55
12,9 - 12,4 - 11,9
Heat
A
3,65 - 3,50 - 3,35
5,60 - 5,35 - 5,10
6,45 - 6,15 - 5,90
7,80 - 7,45 - 7,15
11,4 - 10,9 - 10,5
Air flow
Cool / Heat
m³/min
33,6 / 34,0
32,7 / 31,9
42,6 / 41,5
44,7 / 45,9
73,0 / 73,0
Sound pressure
Cool / Heat (Hi)
dB(A)
46 / 47
46 / 46
47 / 48
48 / 49
52 / 52
Sound power
Cool / Heat (Hi)
dB(A)
64 / 66
64 / 64
64 / 65
66 / 68
70 / 70
Dimension
HxWxD
mm
619 x 824 x 299
619 x 824 x 299
695 x 875 x 320
695 x 875 x 320
996 x 980 x 370
Power supply
Current
Net weight
Piping diameter
32
35
42
50
83
Liquid
kg
Inch (mm)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35) 5)
1/4 (6,35) 5)
3/8 (9,52)
Gas
Inch (mm)
5/8 (15,88)
1/2 (12,70)
1/2 (12,70)
1/2 (12,70) 6)
5/8 (15,88) 6)
Pipe length range
m
3 ~ 15
3 ~ 20
3 ~ 40
3 ~ 40
5 ~ 50
Elevation difference (in / out) 7)
m
15 / 15
15 / 15
15 / 30
20 / 30
15 / 30
Pre-charged pipe length
m
7,5
7,5
30
30
30
Additional gas amount
g/m
10
15
15
17
45
Refrigerant (R32) / CO2 Eq.
kg / T
0,87 / 0,59
1,14 / 0,77
1,15 / 0,78
1,32 / 0,89
2,4 / 1,62
Operating range
Cool Min ~ Max
°C
-10 ~ +43
-10 ~ +43
-10 ~ +43
-10 ~ +43
-10 ~ +43
Heat Min ~ Max
°C
-15 ~ +24
-15 ~ +24
-15 ~ +24
-15 ~ +24
-15 ~ +24
Technical focus
· Modern design with flat face and compact size
· DC fan for better efficiency and control
· Six directional piping outlet
· nanoe™ X (Generator Mark 2: 9,6 trillion hydroxyl
radicals/sec) as standard for better indoor air quality
· Wired remote control CZ-RTC6WBL and CZ-RTC6BL
allows easy system setting via Bluetooth®
· Easy connection and control of external fan or ERV using
the connector PAW-FDC on the indoor unit PCB. The
external device can be controlled by the remote control of
the Panasonic indoor unit
34
Closed discharge port
When the unit is turned OFF, the flap closes completely to
prevent dust getting into the unit and to keep the
equipment clean.
Quiet operation
These units are among the quietest in the industry,
making them ideal for hotels and hospitals.
Piping outlet in six directions
Piping outlet is possible in six directions of; right, right
rear, right bottom, left, left rear and left bottom, making
the installation work more flexible.