07 UK HYDRONICS GEN 24 LR - Flipbook - Page 47
R410A
INDEX HYDRONICS AND ROOFTOPS
CHILLERS AND HEAT PUMPS
Technical performance
Voltage
Power supply 1)
V
Phase
Frequency
400
400
400
400
400
400
400
400
Three phase
Three phase
Three phase
Three phase
Three phase
Three phase
Three phase
Three phase
Hz
Size
ECOi-W AQUA EVO 400-800 C - cooling only P-
50
50
50
50
50
50
50
50
400
450
490
530
600
670
750
800
AQAVE0400CA AQAVE0450CA AQAVE0490CA AQAVE0530CA AQAVE0600CA AQAVE0670CA AQAVE0750CA AQAVE0800CA
Nominal cooling capacity 2)
kW
398,8
446,1
487,7
533,9
597,1
667,3
748,3
797,9
Input power 2)
kW
128,6
142,8
157,1
172,1
192,1
215,0
241,7
257,4
EER 2)
3,10
3,12
3,10
3,10
3,11
3,10
3,10
3,10
EER EC 2)
3,18
3,21
3,19
3,18
3,19
3,18
3,17
3,17
SEER 3) 4)
ηs,c 3) 4)
4,48
4,43
4,50
4,38
4,58
4,65
4,48
4,50
176
174*
177*
172*
180
183
176*
177*
SEER EC 3) 4)
4,65
4,58
4,68
4,55
4,78
4,85
4,65
4,68
hsc EC 3) 4)
183
180
184
179
188
191
183
184
138
Nominal water flow (in the evaporator)
m³/h
68,6
76,8
84,0
91,9
103
115
129
Sound power 5)
dB(A)
92
93
93
94
94
94
95
95
Sound pressure at 10 m 6)
dB(A)
60
61
60
61
61
61
62
62
ECOi-W AQUA EVO 400-800 C S - cooling only
400
450
490
530
600
670
750
800
Nominal cooling capacity 2)
kW
396,0
440,4
480,4
524,8
585,3
651,7
743,4
792,2
Input power 2)
kW
127,2
141,4
156,0
171,4
192,0
215,6
238,6
254,6
EER 2)
3,11
3,11
3,08
3,06
3,05
3,02
3,12
3,11
EER EC 2)
3,20
3,21
3,17
3,15
3,13
3,10
3,20
3,19
SEER 3) 4)
ηs,c 3) 4)
4,50
4,63
4,58
4,78
4,80
4,73
4,73
4,70
177
182
180
188
189
186
186
185
SEER EC 3) 4)
4,68
4,80
4,73
5,05
5,05
4,93
4,93
4,90
hsc EC 3) 4)
184
189
186
199
199
194
194
193
Nominal water flow (in the evaporator)
m³/h
68,1
75,8
82,7
90,4
101
112
128
137
Sound power 5)
dB(A)
86
87
87
87
88
88
89
89
Sound pressure at 10 m 6)
dB(A)
54
54
54
54
55
55
56
56
ECOi-W AQUA EVO 400-800 C HT - cooling only
400
450
490
530
600
670
750
800
Nominal cooling capacity 2)
kW
411,2
455,8
497,3
543,1
607,2
678,7
768,3
820,5
Input power 2)
kW
249,2
123,4
138,4
152,2
167,3
186,4
208,9
234,2
EER 2)
3,33
3,29
3,27
3,25
3,26
3,25
3,28
3,29
SEER 3) 4)
ηs,c 3) 4)
4,78
4,83
4,80
4,83
4,85
4,85
4,70
4,63
188
190
189
190
191
191
185
182
Nominal water flow (in the evaporator)
m³/h
70,8
78,5
85,7
93,6
105
117
132
142
Sound power 5)
dB(A)
93
93
94
94
94
95
96
96
Sound pressure at 10 m 6)
dB(A)
60
61
60
61
61
61
62
62
1) Voltage 400 V +/- 10%. 2) According EN14511-2013: chilled water inlet/outlet temperature: 12/7 °C, outdoor ambient temperature 35 °C DB. 3) ErP compliant: following COMMISSION REGULATION (EU)
2016/2281. 4) According EN14825. 5) Sound powers is declared in nominal full load condition (cooling operation), referring to ISO standard 9614, in accordance with Eurovent certification program. 6) Sound
pressure refer to ISO Standard 3744, parallelepiped shape in a free field on a reflective surface.
* Non ErP compliant: following COMMISSION REGULATION (EU) 2016/2281.
Accessories and options
Accessories and options
Anti‑vibration spring dampers
Power factor corrector capacitors
Automatic circuit breaker
Several communication protocols
Coils treatments
Soft starter
Desuperheater
SRC ‑ mini BMS controller
Fan speed control (‑14 °C in cooling mode – standard as super low noise version)
Unit protection grilles
Hydrokit with 1 or 2 pumps with or without buffer tank (500 l 400‑450, 1 000 l 470‑
670)
Variable pump (for sizes 750‑800 upon request)
Mechanical gauges
Water flow switch
Water filter
Overload protection for compressors
ErP
✔
HIGH
SEER
HIGH
SCOP
4,90
3,99
AIR
COOLED
PLATE HEAT
EXCHANGER
SCROLL
COMPRESSOR
VERY HIGH
PERFORMANCE
ErP: Check ErP compliance according to the configurations in AC SLECT:
https://acselect.panasonic.eu/.
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
47