07 UK HYDRONICS GEN 24 LR - Flipbook - Page 35
R410A
INDEX HYDRONICS AND ROOFTOPS
CHILLERS AND HEAT PUMPS
Technical performance
Voltage
Power supply
V
Phase
Frequency
Hz
Size
ECOi-W AQV 85-140 C - cooling only
400
400
400
400
400
400
Three phase
Three phase
Three phase
Three phase
Three phase
Three phase
50
50
50
50
50
50
85
95
105
115
125
140
P-AQVE0085CA
P-AQVE0095CA
P-AQVE0105CA
P-AQVE0115CA
P-AQVE0125CA
P-AQVE0140CA
Cooling capacity 1)
kW
83,5
93,6
103,0
110,1
121,9
136,6
Input power 1)
kW
26,9
31,0
33,5
36,5
41,1
46,1
3,10
3,03
3,06
3,03
2,98
2,97
EER HSE 1)
3,19
3,10
3,13
3,09
3,05
3,04
SEER 2) 3)
ηs,c 2) 3)
4,55
4,8
4,78
4,8
4,73
4,53
179
189
188
189
186
178
SEER HSE 2) 3)
ηs,c HSE 2) 3)
4,73
4,75
4,95
4,95
4,78
4,6
186
187
195
195
188
181
23,5
EER 1)
Nominal water flow (in the evaporator)
m³/h
14,3
16,1
17,6
19,0
21,0
Sound power 4)
dB(A)
84
84
84
84
88
88
Sound pressure at 10 m 5)
dB(A)
52
52
52
52
56
56
Sound power HPF 4)
dB(A)
92
92
92
92
95
95
Sound pressure at 10 m HPF 5)
dB(A)
60
60
60
60
63
63
ECOi-W AQV 85-140 C S - cooling only
Cooling capacity 1)
kW
Input power 1)
kW
EER 1)
85
95
105
115
125
140
80,6
90,2
98,6
106
119,1
133,1
28
32,6
35,5
38,6
41,1
46,5
2,87
2,76
2,77
2,73
2,90
2,86
2,91
EER HSE 1)
3,00
2,87
2,87
2,81
2,96
SEER 2) 3)
ηs,c 2) 3)
4,75
4,78
4,98
5,0
4,8
4,6
187
188
196
197
189
181
SEER HSE 2) 3)
ηs,c HSE 2) 3)
4,8
4,75
4,88
4,88
4,9
4,7
189
187
192
192
193
185
22,9
Nominal water flow (in the evaporator)
m³/h
13,9
15,5
16,9
18,2
20,5
Sound power 4)
dB(A)
82
82
82
82
86
86
Sound pressure at 10 m 5)
dB(A)
50
50
50
50
54
54
ECOi-W AQV 85-140 C HT - cooling only
85
95
105
115
125
140
Cooling capacity 1)
kW
86,2
96,9
107
115
124
139
Input power 1)
kW
28,1
31,6
33,9
36,4
41,1
46
EER 1)
3,07
3,06
3,15
3,16
3,03
3,03
SEER 2) 3)
ηs,c 2) 3)
4,73
4,75
4,95
4,95
4,78
4,6
186
187
195
195
188
181
24,0
Nominal water flow (in the evaporator)
m³/h
14,8
16,6
18,3
19,8
21,4
Sound power 4)
dB(A)
95
95
95
95
95
95
Sound pressure at 10 m 5)
dB(A)
63
63
63
63
63
63
1) According EN14511-2013: chilled water inlet/outlet temperature: 12/7 °C, outdoor ambient temperature 35 °C DB. 2) ErP compliant: following COMMISSION REGULATION (EU) 2016/2281. 3) According
EN14825. 4) Sound levels are at fully loaded conditions. Sound power values refers to ISO 3744 standard. 5) Sound pressures refer to ISO 3744 standard, parallelepiped shape.
Accessories and options
Accessories and options
Anti‑vibration spring dampers
Power factor corrector capacitors
Automatic circuit breaker
Several communication protocols
Coils treatments
Soft starter
Desuperheater
Unit protection grilles
Fan speed control
Water differential pressure
Hydrokit with 1 or 2 pumps with or without buffer tank
Water filter
Mechanical gauges
Water pressure switch
Overload protection for compressors
ErP
✔
HIGH
SEER
HIGH
SCOP
5,00
4,12
AIR
COOLED
PLATE HEAT
EXCHANGER
SCROLL
COMPRESSOR
VERY HIGH
PERFORMANCE
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
35