07 UK HYDRONICS GEN 24 LR - Flipbook - Page 21
R410A
INDEX HYDRONICS AND ROOFTOPS
CHILLERS AND HEAT PUMPS
Technical performance
Size
ECOi-W AQUA EVO H
Voltage
20
30
P-AQAVE0020HA
P-AQAVE0030HA
V
400
400
Three phase
Three phase
Power supply
Phase
Frequency
Hz
50
50
Cooling capacity 1)
Nominal (Min ‑ Max)
kW
20,0 (9,33 ‑ 28,0)
29,0 (13,9 ‑ 35,9)
Input power 1)
Nominal (Min ‑ Max)
kW
4,15 (2,38 ‑ 6,61)
7,24 (3,51 ‑ 13,0)
EER 1)
Nominal (Min ‑ Max)
4,82 (3,92 ‑ 4,24)
4,01 (3,96 ‑ 2,76)
Cooling capacity 2)
Nominal (Min ‑ Max)
kW
21,0 (6,60 ‑ 25,2)
28,0 (9,43 ‑ 31,1)
Input power 2)
Nominal (Min ‑ Max)
kW
6,95 (2,52 ‑ 10,3)
10,9 (3,14 ‑ 12,4)
EER 2)
Nominal (Min ‑ Max)
3,02 (2,62 ‑ 2,45)
2,57 (3,00 ‑ 2,51)
EER 75%
3,83
3,65
EER 50%
4,53
4,48
EER 25%
3,80
4,79
SEER 3)
ηs,c 3)
3,30
3,98
129
156
3,64
5,92
kW
20,4 (9,94 ‑ 29,4)
26,1 (11,5 ‑ 34,0)
kW
5,02 (2,98 ‑ 8,37)
6,45 (3,01 ‑ 9,80)
4,06 (3,34 ‑ 3,51)
4,05 (3,82 ‑ 3,47)
kW
20,4 (8,90 ‑ 27,4)
26,1 (10,2 ‑ 33,9)
kW
6,44 (3,34 ‑ 9,64)
8,42 (3,97 ‑ 11,6)
3,17 (2,66 ‑ 2,84)
3,10 (2,57 ‑ 2,91)
3,75
3,68
Nominal water flow (in the evaporator)
m³/h
Heating capacity 4)
Nominal (Min ‑ Max)
Input power 4)
Nominal (Min ‑ Max)
COP 4)
Nominal (Min ‑ Max)
Heating capacity 5)
Nominal (Min ‑ Max)
Input power 5)
Nominal (Min ‑ Max)
COP 5)
Nominal (Min ‑ Max)
SCOP 6) 7)
Energy efficiency class 6) 7)
ηs,h 6) 7)
A+++ to D
SCOP 6) 8)
Energy efficiency class 6) 8)
ηs,h 6) 8)
A+++ to D
A+
A+
147
144
3,00
2,95
A+
A+
117
115
5,92
Nominal water flow (in the evaporator)
m³/h
3,64
Sound power 9)
dB(A)
74
75
Sound pressure at 10 m 10)
dB(A)
43
44
Physical features
ECOi-W AQUA EVO H
Dimension
HxWxL
mm
Operating weight
20
30
1 615 x 539 x 1 477
1 615 x 539 x 1 477
260
275
Male gas threaded
Male gas threaded
1¼
1¼
kg
Water connections
Type of water connections (evaporator)
Water inlet/outlet diameter
Inch
1) According EN14511-2013: chilled water inlet/outlet temperature: 23/18 °C, outdoor ambient temperature 35 °C. 2) According EN14511-2013: chilled water inlet/outlet temperature: 12/7 °C, outdoor ambient
temperature 35 °C DB. 3) According to EN14825 standard. 4) According EN14511-2013: warm water inlet/outlet temperature: 30/35 °C, outdoor ambient temperature 7 °C DB/6 °C WB. 5) According EN145112013: warm water inlet/outlet temperature: 40/45 °C, outdoor ambient temperature 7 °C DB/6 °C WB. 6) ErP compliant: following COMMISSION REGULATION (EU) No 813/2013. 7) According to EN14825
standard - low temperature application (35 °C). 8) According to EN14825 standard - medium temperature application (55 °C). 9) Sound levels are at fully loaded conditions. Sound power values refers to ISO 3744
standard. 10) Sound pressures refer to ISO 3744 standard, parallelepiped shape.
Accessories and options
Accessories and options
Buffer tank placed under unit
In/out valve kit
Chassis acoustic insulation
Remote ON / OFF
Coils treatments
Water flow switch
ErP
✔
HIGH
SEER
HIGH
SCOP
3,98
3,75
AIR
COOLED
PLATE HEAT
EXCHANGER
SCROLL INVERTER
COMPRESSOR
DHW
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
21