R410A
GENERAL INDEX
ECOi-RT C/H · R410A
Rooftop cooling only and heat pump units.
Cooling capacity: 48,1 to 219,1 kW.
Heating capacity: 50,7 to 214,4 kW.
The range at a glance
· 2 versions: C (cooling only) and H (heat pump)
· SEER up to 3,94 and SCOP up to 3,23
· 10 sizes
· Nominal air flow from 9 720 to 32 000 m³/h
· Additional heaters available
· Many aeraulic configurations
· 2 energy recovery system configurations (RECO and
TRECO)
Advantages
· Very high performances: A class EER and COP
· Low energy consumption EC fans
· Wide operating limits
· Thermal/acoustic insulation: double skin (25 mm
glasswool)
· 100% factory tested
Equipment
Operating limits
To be confirmed with AC SELECT:
https://acselect.panasonic.eu/
Ambient temperature (DB).
-10 °C 1)
50 °C
-15 °C
-20
-15
18 °C
-10
-5
0
5
10
15
20
25
30
35
40
45
50
55
35
40
45
50
55
Temperature before indoor coil 2).
12 °C
26 °C
10 °C
-20
-15
-10
-5
0
5
10
27 °C
15
20
25
30
1) Using fan speed control option. 2) Cooling: °C (WB). Heating: °C (DB).
114
Accessories and options
Accessories and options
AC HP plug fan
G4, G4+F7 or G4+F9 filters
Adjustable roof curb
Gas heater (upon request)
Anti‑vibration mounts
Hot water coil
Clogged filter sensor (1 or 2 stages)
Local additional remote keyboard
Compatible container transportation
Compressor soft starter
Many aeraulic configurations (bottom,
side, front, top)
EC or EC HP plug fan
Modbus / BACnet
Electric heaters
RECO or TRECO energy recovery
Energy recovery system
Room temperature sensor
Epoxy treatment (indoor/outdoor coils)
Sensors (VOC, enthalpy, CO2)
Fan speed control
Smoke detector
· 2 refrigerant circuits for optimised defrosting logic. They
are both completely closed in a separate compartment to
reduce noise level. Each circuit comprises of Scroll
compressor(s) (2 per circuit from size 160), indoor and
outdoor coils, 4 way reversing valve (H type), filter dryer,
sight glass, thermostatic or electronic expansion valve
(from 160 to 210), high and low pressure switches,
defrosting pressure switch, intake temperature sensor,
and a liquid accumulation bottle (for sizes from 160 to 210)
· 2 or 4 Scroll compressors ‑ 1 per circuit from 55 to 140
and 2 per circuit for 160 to 210 assembled together in
tandem. Each compressor is equipped with a crankcase
heater and mounted on rubber pads to eliminate noise and
vibration transmissions. The motors are equipped with
overload protection and have direct start‑up. A phase
sequence monitor is supplied as standard
· The controls are grouped and wired in the unit, factory
tested and shipped READY TO USE. They are located in a
sealed compartment that is isolated from the air flow. The
electrical equipment is compliant with EC standards and
EN60204‑1
· The outdoor and indoor heat exchangers are made of
seamless copper tubes mechanically expanded into
aluminium fins. Outdoor coils are largely dimensioned to
optimise performance and defrost cycles. They are also
equipped with a protective grille to prevent shocks ‑
Bluefin treatment applicable to heat pump type
· The unit casing is of heavy duty galvanized steel, painted
with a special process to ensure a perfect protection
against corrosion (RAL 9001). The complete unit is covered
with double skin panels to ensure perfect thermal
insulation. For full unit access, all service panels are
removable. Under the indoor heat exchanger, an
extractable condensate drain pan allows hygienic cleaning.
· The indoor fan(s) are plug type with AC or EC motors; low
pressure or high pressure according to the configuration
selected by the customer.