Cinema TheatrKiamaList of reqairements.(Continued.)
sides above rnid-landing and upper flight to be carried
up solidly to under side of gallery, with enclosures a.i
gallery tiers 31 6* high and the well holes covered as
far as possible with strong wire netting on stout pipe
framing. The lower flights of stairs may have wire
netting 5' 6" high above outer string as specified.
,
-
11. If collapsible gates are fixed to vestibule, they must
be fastened with a device operated by a key only to
maintain them open during entertainments.