Proposed Cinema Theatre, Kiarna.
(Continued.)
IT EMS OF REQUIREMENT.
31.
Exit doors to be made to open outwards and fastened with
patent automatic panic bolts, in accordance with Regulation
b4.
2.
The words "THIS VAY OUT" or "iT" to be legibly pal ed
in 4 in, letters over each exit door.
3,o
Candle -lamps or oil lamps to be fixed oveach exit, ara
securely fastened with strong brackets to the wall.
Tne iixeu foriiis or seats to U e restrictea to ta a
ments set forth in Regulation No. 71, namel'
tweeri
skace of at least OLC fuOt o oe allowed
the front of one seat and the baclç6f the next,
measured between perpendiculars.
(b) Passages or gangways not less than 3 ft. 6 ino wle
shall be formed leading direct to the óxit doors,
and gangways 3 ft. 6 in. wide shall be provided in
rows of seating in such a way that no chair or seat
shall have more than six chairs intervening between
it and a passage or gangway, or more than fourteen
chairs in a row between any two passes or gangways.
In addition to the openings in walls, gable louvres, and
roof cowls, a sufficient number of inlet air vents to be
provided in walls at a suitable height, say 5' 6" above
floor.
Lamps for lighting to be placed sufficiently high to be
out of the reacIf the public.
The operating box must not be less than 10 ft. x 8 ft.,
with a separate room provided for re—winding of fflms,both
of which must be4f approved fir'esisting consruction.
The door or doors must open outwards and be self—closing,
and the openings for projection and observation must not
exceed 8 in. square. A metal shutter of approved design
to cover all, the opening cyk itted with device to operate
same immediately in case of fire occurring in the
operating box must be provided. A ventilator not less
than 18 in* in diameter to be provided through the roof
immediate1y over the machine.
A 2W fire hydrant with hose, nozzle, fittings and meei
swinging bracket of T.S.W. Fire Brigade pattern to be
provided and placed where directed, and enclosed in a
having doors with panels filled in with *"' mesh wire
rietting, and the words "FIRE HOSE" painted onn, in red
block lettering. A. hand chemical extinguisher, two
buckets and a blanket to be provided for use in operating
box.
'
Adequate sanitary conveniences for both sexs to be
provided to the satisfaction of the local sanitary
authorities.
The
not
not
to
side doors of stalls to be 8' 0" and the front one.s
less than 4' 6" wide in the clear, and the staircases
to be under 5' 0" in width. The start steps of stairs
be,i
ful width and not splayed as shown, and the outer
S ldes/