EN katalógus általános Kolver 2022 - Flipbook - Page 24
Fixture Mount Screwdrivers / Torque & Angle Series
Torque & Angle Screwdrivers for Automation | Torque range 0.02 − 50 Nm
Automation requires accurate torque controlling techniques. TA
automated systems feature advanced monitoring strategies such as
torque and rotation angle of the screw, for precise torque and angle
control on all automated operations.
The Torque/Angle Control
The main parameters to be controlled are the tightening torque and
the rotation angle of the screw, either with torque or angle priority. The
screwdriver stops automatically when the pre-set angle and torque value
have been reached and an indication of OK cycle (green led turned on)
is given, otherwise a red led turns on if the tightened screw doesn’t
match the pre-set parameters. The final torque and angle values are also
displayed.
Easy interface
TA Screwdrivers work in combination with EDU2AE/TOP/TA control units,
which allow to set, change and save all parameters via PC, USB key and a
wide range of I/O connections for an easy interface with your PLC, robot
or machine.
Plenty of options
PLUTO, MITO and NATO automated torque & angle screwdrivers cover
a wide torque range of 0.1-50 Nm: choose the tool that best suits your
application and set the desired working cycle through TOP/TA control
units. You can set 8 independent programs either directly on control unit
or remotely.
TA automated screwdrivers give you total control over automated
applications.
Industry 4.0
Interconnection, automatic control and continuous monitoring are
fundamental aspects of Industry 4.0.
Through EDU2AE/TOP/TA control units you can easily manage input and
output signals such as start, stop, error and more.
You can also get data reports of the full tightening procedure on PC, USB
key or serial connection.
24
EDU2AE/TOP/TA Torque and Angle Functionalities
Torque Mode
It’s the most common mode. If the final
torque and angle values are within the preset minimum and maximum values, the screw
is tightened correctly and the controller will
give an OK message.
If the torque and/or angle are outside the
pre-set values, the screw will be considered
incorrectly tightened and the controller will
give an error message.
Angle Mode
This mode gives priority to the angle to be
reached. Starting from the pre-set threshold
torque, the system will start counting the
degrees and when the pre-set angle is
reached the screwdriver will stop.
The control unit will give an OK or NOK
message depending on whether the screw is
tightened correctly or not. It is also possible
to set minimum and maximum values within
which the set angle must be reached.
ESD-safe housing