Best practices book - Flipbook - Page 122
BEST PRACTICES | 113
-
-
-
-
-
3. Inspect driving operations and maintain complete and accurate
records for each element.
-
X
X
2. Determine capacities of test elements and conduct additional load
tests, as required.
-
X
BEST PRACTICES | 113
determined by the Registered Design Professional in Responsible
Charge.
7. For specialty elements, perform additional inspections as
6. For concrete elements and concrete-filled elements, perform
additional special inspections in accordance with Section 1705.3.
5. For steel elements, perform additional special inspections in
accordance with Section 1705.2.
record tip and butt elevations and document any damage to
to foundation element.
determine required penetrations to achieve design capacity,
of hammer, record number of blows per foot of penetration,
4. Verify placement locations and plumbness, confirm type and size
1. Verify elements, materials, size, and lengths comply with the
requirements.
-
X
REQUIRED SPECIAL INSPECTIONS & TESTING
PLEASE PROVIDE THE NAME AND PHONE
NUMBER OF THE SPECIAL INSPECTION
AGENCY AND INDIVIDUAL PERFORMING
THIS SPECIAL INSPECTION SERVICE IN THE
SPACE BELOW.
• Perform Special Inspections and Tests during installation of driven deep foundation elements as specified in Table 1705.7.
• Determine compliance using the approved geotechnical report (section 1803.6) and the construction documents prepared by the Registered
Design Professionals.
CHECK BOX
BELOW IF CONTINUAL PERIODIC
REQUIRED
7.
DRIVEN DEEP FOUNDATIONS (1705.7 & TABLE 1705.7):