Habonim Catalog Interactive 2024 V04 15022024 - Catalog - Page 447
C15-C90M
CompAct Actuators Configurations
The actuator can be configured for either spring return or double-action operation. In both
cases the air supply to drive the pistons flows into Port A of the NAMUR cover. Port A is
connected to the center chamber, and Port B is connected to the four outside chambers.
Spring return (fail-safe)
Pressure entering Port A to open:
Pressure exiting Port A to close:
• Center chamber is pressurized and
pistons move outward
• Air released from center chamber
• Springs are compressed
• Pinion rotates clockwise
• Springs drive pistons inward
• Pinion rotates counterclockwise
ccw
cw
Double action (increased torque)
Pressure entering Port A to open:
Pressure entering Port B to close:
• Center chamber is pressurized
• Outside chambers are pressurized
• Pistons move outward
• Pistons move inward
• Pinion rotates counterclockwise
• Pinion rotates clockwise
ccw
cw
ACTUATION
447