UL Site Starters Ordering Guide - Flipbook - Page 9
TOTAL SYSTEM SOLUTIONS™
SELECTING A CONTROLLER
TURBINE PUMP
INTERFACE
SITE STARTER
When combined with an EVO™ Series Automatic Tank
Gauge, both the MagVFC or the STP-SCI can be used to
achieve Turbine Pump Interface. Choose between the
following features to select the preferred controller option.
LEAK DETECTION
TANKS
Feature
- OR -
Statistical Continuous Automatic Leak Detection (SCALD) is a
software option on EVO™ Series automatic tank gauges. It allows a
site that is continuously open to still perform 0.2 gph in-tank leak
detection tests. This allows you to maintain compliance testing
without having to shut down a tank.
3
1
LINES
Guardian
√
√
Eliminate STP-DHI Boxes
√
√
Eliminate Relay Module
√
√
Pump Protection
√
√
Fixed Speed Pumping
By adding a TS-LS500 line leak detector, you get highly accurate
electronic line leak detection for your lines. The system connects
with a EVO™ Series tank gauge to actually learn the characteristics
of each line. This eliminates possible configuration errors and
provides unparalleled leak detection accuracy.
Dispenser Hook Direct to Tank Gauge
Use this typical 2 Hp system setup diagram to help you place your next
order. Combine EVO™ Series Automatic Tank Gauges with FE PETRO®
submersible pumping systems for enhanced remote pump monitoring
and control. Be sure to always consult local regulations.
MagVFC
Fault Protection
√
Soft Start-Up
√
11
A FMP-ULS may be used in
both dispenser sumps and tank
sumps when a discriminating
sensor is not required.
10
12
• This system includes submersible turbine pump (STP) and controller
options for both 2 hp variable speed and 2 hp fixed speed pumping
systems. Choose one type of STP and controller sets per site.
10
• YYY in inventory control probe model number = variable product
length based on tank diameter. Use the “Select a Probe Model”
chart to choose your custom probe model number.
TPI is a standard feature on all EVO™ Series Automatic Tank Gauge
(ATG). Simply pair the ATG with a pump controller to take control
of your submersible pumps and get features like pump-in-water
detection, dry tank detection, clogged intake escalation, overfill
protection, tank leveling, and tank priority.
TANK INVENTORY & LEAK DETECTION MONITORING
FMP-LL3 bottom-mounted probes provide accurate inventory
levels and leak detection monitoring in storage tanks. Select the
appropriate float kit for your application. Float kits include a
product and water level float.
© 2021 Franklin Fueling Systems. All Rights Reserved.
FFS-0321 12-21
13
- OR -
7
5
- OR -
4
CONTAINMENT MONITORING
TURBINE PUMP INTERFACE
9
SENSORS
IMPORTANT NOTES
A FMP-ULS liquid sensor can be used to detect the presence of
liquid in a sump - OR - a FMP-DTS-U discriminating turbine sump
sensor or FMP-DDS-U discriminating dispenser sump sensor can
be used to both detect liquids and distinguish between hydrocarbons
and non-hydrocarbons.
√
Variable Speed Pumping
10
10
EQUIPMENT LIST
Item
1
2
3
Description
EVO™ Series ATG (base models)
2 Hp Variable Speed STP
2 Hp Fixed Speed STP
6
4
Model
EVO200/400/550/5000/600/6000
ISTAPKM2
STPAPKM200-VL2
MagVFC Variable Speed Controller
5874202800
Guardian Series™ Fixed Speed Controller
2
SELECT A PROBE MODEL
5800100220
Tank
Dia.
FMP-ULS
Model
Model
2'
FMP-LL3-29
10'
FMP-LL3-125
Low Level Water
For Diesel
3'
FMP-LL3-41
10'6"
FMP-LL3-131
Gasoline
4'
FMP-LL3-53
11'
FMP-LL3-137
Phase Separation
(Ethanol)
Universal Liquid Sump Sensor
5
Discriminating Dispenser Sump
Brite™ Sensor
FMP-DDS-U
6
Discriminating Turbine Sump
Brite™ Sensor
FMP-DTS-U
5'
FMP-LL3-65
12'
FMP-LL3-149
7
Leak Detection & Inventory Probe
FMP-LL3 (see table to right)
5'4"
FMP-LL3-69
13'
FMP-LL3-161
8
4" Product and Water Level Float Kits
See "Select A Float Model" table
6'
FMP-LL3-77
14'
FMP-LL3-173
9
4" Probe Install Kit
TSP-K4A
6'4"
FMP-LL3-81
15'
FMP-LL3-185
REB-C-0075
7'
FMP-LL3-89
16'
FMP-LL3-197
FMP-LL3-101
17'
FMP-LL3-209
FMP-LL3-113
18'
FMP-LL3-221
¾" Conduit Entry Boot
11
Probe Access Manhole
20URTATG
8'
12
4" Flexible Entry Boot
FEB-400-F
9'
13
Line Leak Detection Transducer
TS-LS500/3 (3 lines)
Description
Tank
Dia.
4
10
SELECT A FLOAT KIT MODEL
Diesel
Model
8
TSP-IDF4
FMP-IDF4E
TSP-IGF4
TSP-IGF4P
Density Diesel
TSP-IDF4D3
Density Gasoline
TSP-IGFD3
8