ORDERING INFORMATION
High Capacity Submersible Turbine Pump Model Designation System
A typical turbine model designation has up to five components to define the pump being supplied as follows:
STP XXXXX Y - A - B
STP = Basic Model Designation
Note: Standard models up to 10% ethanol capable.
XXXXX = Factory Installed Options
HCP model designations may include one or more of the following characters in alphabetical order:
F = Floating suction adapter (3" NPT male adapter)
*R = Model R check valve (24 psi relief/22 psi reset for PLLD)
*If not otherwise specified, all HCP models supplied with standard model check valve (40 psi relief/35 psi reset for MLD, TS-LS300, and TS-LS500).
Y = Pump Motor Horsepower Rating
3 = 3 hp fixed speed, 208-230 VAC
5 = 5 hp fixed speed, 208-230 VAC
5H = 5 hp fixed speed, 460 VAC
5G = 5 hp fixed speed, 575 VAC
A = Model Length
Model length is expressed as three numeric characters that indicate the length of the HCP from the turbine manifold bottom
to the pump motor inlet in inches, available from 60" to 200" (additional charge for models 132" and longer)
B = Riser Pipe Length
Riser pipe length is expressed as two numeric characters that indicate the total length of the riser in inches. Riser pipes are
available from 6" to 60" in three inch increments (additional charge and lead time for risers 27" or longer).
High Capacity Turbine Pumps (Fixed Length Only)**
Model
Description
STP3
3 hp 6" STP, three-phase 208-230 VAC
STP5
5 hp 6" STP, three-phase 208-230 VAC
STP5H*
5 hp 6" STP, three-phase 460 VAC
STP5G*
5 hp 6" STP, three-phase 575 VAC
*
Please call customer service for lead time on this item.
Notes:
1. STP models are listed for compatibility with fuel mixtures containing up to 10% ethanol with gasoline and up to 5% Biodiesel with diesel fuels.
2. All models are supplied with a standard check valve unless factory option “R” is specified.
3. All above models require three-phase, 60 Hz incoming power.
4. 6" riser pipe, if supplied locally, must be 6 5⁄8" OD by ¼" WT tubing.
5. For riser pipe lengths 27" to 60" long, additional charges apply (consult factory for lead times).
** Model length (A) defined as the dimension from the turbine manifold bottom to pump motor inlet. Model length can be minimum of 60" to a maximum of 200". Adder
(P/N 401190911) applies if model length is 132" to 170" or adder (P/N 401190914) applies if model length is 171" to 200" (charge is for additional packaging). Please call
Customer Service for lead times.
Factory Installed Options
Model
60
Description
F
Floating suction adapter, 3" male NPT (must be ordered with STP)
R