UL Catalog 2024-2025 - Flipbook - Page 59
SPECIFICATIONS
- Fixed speed, 3450 rpm, multi-stage
centrifugal type pump motor with built-in,
automatic, thermal overload protection
Pump motor
- High capacity pump models require
three-phase, 60 Hz incoming power
Standard features
- High capacity pump models are available as
208-230 VAC, 460 VAC or 575 VAC versions
Power
requirements
SUBMERSIBLE
PUMPING SYSTEMS
- High capacity pump 60 Hz models are
available as two-stage versions only
- High capacity pump models are available
in 3 hp and 5 hp versions
- Fixed speed, 3450 rpm, multi-stage
centrifugal type pump motor with built-in,
automatic, thermal overload protection
- STP-SCIII three-phase Smart Controllers and
STP-CB3/5 three-phase control boxes are
available for high capacity pump control
- High capacity pump 60 Hz models are
available as two-stage versions only
- Max. liquid viscosity: 70 SSU at 60° F (15° C)
- Standard models are UL and cUL listed for
fuel mixtures containing up to 10% ethanol
with gasoline, and 20% MTBE, 20% ETBE or
17% TAME with gasoline
- Consult factory for applicable approvals
Approvals /
Certifications
- Franklin Fueling Systems is an ISO 9001
Certified Manufacturer
Liquid
compatability
- High capacity models can also be used with
diesel fuels, fuel oils, kerosene, Avgas, and jet
fuels in a non-gelled pourable state
- All wetted elastomers are made of a high
grade, fluorocarbon compound
5 hp Fixed Speed High Capacity Performance Chart
3 hp Fixed Speed High Capacity Performance Chart
110
90
100
80
90
Total Head in Feet (ft.)
Total Head in Feet (ft.)
70
60
STP3 3 hp
50
40
80
70
STP5 5 hp
60
50
40
30
30
20
20
10
10
0
0
0
20
40
60
80
100
120
140
160
180
200
Flow in Gallons per Minute (gpm)
Note: Performance based on pumping solvent (0.78 specific gravity). Pressure is taken at the manifold discharge
outlet. STP3 models are powered by a three-phase, 60 Hz, 208/230 Volt power supply.
0
20
40
60
80
100
120
140
160
180
200
220
240
260
280
Flow in Gallons per Minute (gpm)
Note: Performance based on pumping solvent (0.78 specific gravity). Pressure is taken at the manifold discharge
outlet. STP5 models are powered by a three-phase, 60 Hz, 208/230 Volt power supply.
59