UL Catalog 2024-2025 - Flipbook - Page 402
SPECIFICATIONS CONTINUED
Environmental
Operating Temperature
-40° C to 45° C (-40° F to 113° F)
Storage Temperature
-40° C to 85° C (-40° F to 185° F)
Operating Humidity
0 to 90% relative humidity
Dimensions - Enclosed RCS
60" H x 30" W x 7" D
Weight - Enclosed RCS
200 lbs (90.7 kg) or less
Line Voltage
110-120 V
Line Frequency
50-60 Hz
Location
Install the unit indoors, in a non-hazardous environment
Circuit Breaker
20A dedicated circuit breaker required
Approvals/Certifications
UL 508A
1-Ph Modules
Input Terminals
1 (Line and Neutral)
Output Terminals
1 (Line and Neutral)
Operating Voltage
100-240 VAC
Operating Current
15A AC
Operating Frequency
50/60Hz
Pump Modules
Input Terminals
3
Output Terminals
3
Operating Voltage
100-240 VAC
Operating Current
35A Resistive, 250 VAC 5HP
Operating Frequency
50/60Hz
ACIO Module
Input Terminals
4 (Line and Neutral)
Output Terminals
2 (Supply and Output)
Operating Voltage
100-240 VAC
Operating Input Current
35 mA
Operating Output Current
0.3 A
Operating Frequency
50/60Hz
NEC® Compliance
402
Emergency Disconnects Controlled by E-Stop
NEC® 514.11 & NFPA® 30A
Dispenser Hook Isolation
NEC® 514.13
Low Voltage Dispenser Data Disconnects
NEC® 514.13