SPECIFICATIONS CONTINUED
2 Hp Variable Speed Pump Performance Chart
140
130
Two MVS2, Manifolded 2 hp
MagShell ™ Variable Speed
Pumps
120
110
Total Head in Feet (ft.)
100
90
80
70
One MVS2, 2 hp MagShell™
Variable Speed Pump
60
50
40
30
20
10
0
0
20
40
60
80
100
120
140
160
180
200
220
Flow in Gallons per Minute (GPM)
Performance based on pumping gasoline (0.76 specific gravity). Pressure is taken
at the manifold discharge outlet. ISTM and STPMVS2 turbines can only be
powered by a MagVFC with single or three phase incoming power.
2 Hp Fixed Speed Pump Performance Chart
140
140
130
130
120
120
Two STPM200, Manifolded 2
hp MagShell™ Fixed Speed
Pumps
110
Two STPHM200
Manifolded 2 hp High
Pressure MagShell™ Pumps
110
100
Total Head in Feet (ft.)
Total Head in Feet (ft.)
2 Hp High Pressure Fixed Speed Pump Performance Chart
90
80
70
60
50
100
90
80
70
60
50
One STPM200 2 hp
MagShell™ Fixed Speed
Pump
40
40
30
30
20
20
10
10
0
0
20
40
60
80
100
120
140
160
180
200
220
One STPHM200 2 hp
High Pressure MagShell™ Pump
0
0
20
40
60
80
100
120
140
160
180
200
220
Flow in Gallons per Minute (gpm)
34
Flow in Gallons per Minute (GPM)
Flow in Gallons per Minute (GPM)
Performance based on pumping gasoline (0.78 specific gravity). Pressure is taken
at the manifold discharge outlet. STPM200 are powered by a single-phase, 60 Hz,
208/230 Volt power supply.
Performance based on pumping gasoline (0.78 specific gravity). Pressure is taken
at the manifold discharge outlet. STPHM200 are powered by a single-phase, 60
Hz, 208/230 Volt power supply.