UL Catalog 2024-2025 - Flipbook - Page 33
SPECIFICATIONS
General
Liquid Compatibility
Variable speed models Only available in variable lengths
Models are available in variable
length and fixed length options
Check valve
2¾" diameter fluorocarbon seal
constructed with cast aluminum body
and steel backing washer
Pressure relief valve
Available in four pressure relief settings,
integral to check valve. Standard model
relieves at 40 psi and resets above 35 psi
Syphon
Venturi-type syphon primer supplied with
every submersible. Syphon check valve and
secondary syphon sold separately
70 SSU at 60° F (15° C)
STP variable speed
STP variable speed models are UL and cUL
listed for fuel mixtures containing up to 10%
ethanol, and 20% MTBE, 20% ETBE or 17%
TAME with gasoline
STPAG
(AG compatible)
STPAG (AG compatible) models are UL
listed for fuel mixtures containing diesel fuel
with up to 20% Biodiesel, 100% Biodiesel,
up to 85% ethanol with gasoline, and 20%
MTBE, 20% ETBE or 17% TAME
with gasoline
Variable speed
(non-AG)
All variable speed (non-AG) models can
also be used with diesel fuels, fuel oils,
kerosene, Avgas and jet fuels in a
non-gelled pourable state
Air eliminator
Every submersible includes a tank return
path with one-way check valve to provide
active air elimination
2 Hp fixed speed
Electrical disconnect
Electrical yoke for positive contractor
disconnect during service
2 Hp fixed speed models can also be used
with diesel fuels, fuel oils, kerosene, Avgas
and jet fuels in a non-gelled pourable state
Approvals/
Certifications
- cULus listed
- Consult factory for applicable approvals
Wetted elastomers
All wetted elastomers are made of a high
grade, fluorocarbon compound
Variable Speed Pump Motor
4 Hp
Variable speed, two-stage centrifugal type
pump motor with integral, automatic,
thermal overload protection
Max. pressure
Selectable operating pressure on MagVFC™
between 24 psi and 42 psi deadhead
MagShell®
Available with MagShell® which results in
45% increased flow area around motor
SUBMERSIBLE
PUMPING SYSTEMS
Fixed speed
Max. liquid viscosity
Variable Speed Power Requirements
Variable speed pumps
Can only be controlled by a MagVFC™
variable frequency controller
VS2 models
Can operate with single- or three-phase
incoming power supply to the MagVFC™
Incoming power
Incoming power supply to the MagVFC™
can be 200-250 VAC, 50 or 60 Hz
Outputs
MagVFC™ outputs a three-phase, variable
frequency signal, valid for FE PETRO®
variable speed pumps only
Max. line draw
MagVFC™ max. line draw: 20 Amps
Max. motor draw
7 Amps
Fixed Speed Pump Motor
2 Hp fixed speed
2 Hp fixed speed models require
single-phase, 208-230 VAC, 60 Hz
incoming power
Standard pressure
Standard pressure (M200, two-stage)
model, max. pressure = 36 psi
High pressure
High pressure (HM200, three-stage)
model, max. pressure = 45 psi
MagShell®
Available with MagShell™ for 45%
increased flow area around motor
Fixed Speed Power Requirements
Incoming power
2 Hp fixed speed models require
single-phase, 208-230 VAC, 60 Hz
incoming power
2 Hp fixed speed
2 Hp fixed speed models incorporate a
starting and running capacitor, with internal
bleed resistor, rated 370 Volt,
40 microfarad
Single phase
SPGC-220 single-phase Guardian Series™
Controllers and STP-CBS single-phase
control boxes are available for 2 hp
pump control
Max. motor draw
12 Amps
33