UL Catalog 2024-2025 - Flipbook - Page 321
ORDERING INFORMATION CONTINUED
Intrinsically Safe Modules
Model
Description
FMP-485IS
RS-485 Module | 4 MSH inputs (allows for 24 total inputs) | Compatible with FMP-MSH multiplexing sensor hubs (EVO™ 600/6000 only)
FMSP-485IS
Spare/Replacement RS-485 Module
FMP-UDP9
UDP Module | 12 inputs | Compatible with FMP-LL3-XXX and FMP-LL3-XXX-I probes, FMP-UHS and FMP-ULS sensors,
and FMP-XXX-U sensors (EVO™ 600/6000 only)
FMSP-UDP9
Spare/Replacement UDP Module
TS-2WSNS
2-Wire Sensor Module | 12 inputs | Compatible with FMP-HFS2, FMP-UHS, FMP-ULS, TSP-HLS-XX, and TSP-HLS-XX/SS sensors
TSSP-2WSNS Spare/Replacement 2-Wire Sensor Module
TS-3WSNS
3-Wire Sensor Module | 8 inputs | Compatible with FMP-DDS*, FMP-DIS*, FMP-DTS*, FMP-EIS*, FMP-HIS*, FMP-HIS-XL*,
FMP-UHS*, FMP-ULS*, TSP-DVS, TSP-HLS-XX, and TSP-HLS-XX/SS sensors
TSSP-3WSNS Spare/Replacement 3-Wire Sensor Module
TS-PRB
Probe Module | 12 inputs | Compatible with TSP-LL2-XXX, TSP-LL2-XXX-I, FMP-LL3-XXX, and FMP-LL3-XXX-I probes;
TSP-DMS-XX and FMP-XXX-U sensors; and VFM vapor flow meters
TSSP-PRB
Spare/Replacement Probe Module
TS-420IB
4-20 mA Module | 8 inputs | Intrinsically Safe | Compatible with TS-LSU500/X transducers and FMP-TEM, TS-VPS, and TS-SCCM sensors
TSSP-420IB
Spare/Replacement 4-20mA Module, Intrinsically Safe
Note: EVO™ 600/6000 are backwards compatible with the TSP-XXX versions of sensors denoted with "*".
Non-Intrinsically Safe Modules
Description
TS-10ARLY
10 Amp Relay Module | 6 outputs | 10 Amp | Compatible with high power dispenser shutdown control functions
TSSP-10ARLY
Spare/Replacement 10 Amp Relay Module
TS-420EXP
4-20 mA Module | 8 inputs | Explosion-Proof | Compatible with TS-LSU500/X transducers and FMP-TEM, TS-VPS,
and TS-SCCM sensors
TSSP-420EXP
Spare/Replacement 4-20mA Module, Explosion-Proof
TS-ACI
AC Input Module | 12 inputs | Compatible with dispenser hook signal monitoring functions
TSSP-ACI
Spare/Replacement AC Input Module
TS-IO
Input Output Module | 4 4-20 mA outputs | 8 3-240 VAC/DC inputs | Compatible with remote monitoring control and
building monitoring system interfacing functions
TSSP-IO
Spare/Replacement Input/Output Module
TS-RLY
Relay Module | 8 outputs | 2 Amp | Compatible with TS-LSU500/X transducers, TPI, and TS-SCCM control functions
TSSP-RLY
Spare/Replacement Relay Module
FUEL MANAGEMENT
SYSTEMS
Model
Expansion Consoles
The EVO-EXPC2 must follow the same guidelines as the EVO™ 600, and the EVO-EXPC must follow the same guidelines as the EVO™ 6000.
Model
Description
EVO-EXPC
Secondary console to add eleven additional plug-in modules to the primary EVO™ 600/6000, comes without a display or printer
EVO-EXPC2
Secondary console to add six additional plug-in modules to the primary EVO™ 600/6000, comes without a display or printer
EVO™ 600/6000 Hardware & Software Field Upgrades
The following software and hardware options can be added to customize your EVO™ once it's been installed in the field.
Hardware Field Upgrades
Model
Description
EVO-DISPREP
Display upgrade for an EVO™ 600/6000, EVO™ 550/5000 with existing Interface Board REV 4 or lower
EVO-TMPTR
Thermal internal printer assembly upgrade for an existing EVO™ 600/6000, EVO™ 550/5000, comes with one roll of printer paper
FMP-WIFI
WiFi upgrade for an existing EVO™ 200/400, EVO™ 600/6000, includes 4.5" antenna
EVO-DIMIB
Internal Dispenser Interface Module upgrade for an existing EVO™ 600/ 6000, dispenser interface cable must be ordered separately
EVO-LCD
Display upgrade for an EVO™ 600/6000 with existing Interface Board REV 5 or higher (for REV 4 or lower, use EVO-DISPREP)
Dispenser Interface Module Cables
Model
Description
TSP-BDCBL
Bennett® 515 only cable
TSP-GDCBL
Gilbarco® cable
TSP-GSDCBL Gilbarco® G-Site™ cable
TSP-WDCBL
Wayne™ cable
321