UL Catalog 2024-2025 - Flipbook - Page 190
FUSION DUCTED
ENTRY BOOT
APT® fusion ducted entry boots provide a watertight seal
between XP pipe and polyethylene constructed containment
sumps. Utilizing the electrofusion welding process, the entry
boot, ducting, and sump become one solid structure, creating
a watertight entry into the containment space.
HIGHLIGHTS
• The two-piece design includes the entry boot itself and a
reducer fitting which seals off the secondary XP Pipe layer
inside of the sump.
• Creates watertight entries into containment sumps.
• Features integrated test ports on both the entry boot and
reducer fitting.
• The electrofusion welding process is safe and simple to
complete in any climate and virtually any weather condition.
• The welding process uses the lightweight, portable
electrofusion welder unit to form watertight connections.
SPECIFICATIONS
• Ducting is recommended for future-proofing sites to
accommodate pipe changes or as a pull chase for future
station expansion.
Components
• Available for use with 1½", 1¾", and 2" XP pipe diameters.
ORDERING INFORMATION
Model
Description
FWEB-150-SC
Fusion ducted entry boot for 1½" XP pipe
FWEB-175-SC
Fusion ducted entry boot for 1¾" XP pipe
FWEB-200-SC
Fusion ducted entry boot for 2" XP pipe
EF1-230V
230 Volt handheld electrofusion welder
408032001
Step up transformer for handheld welder unit
304-CLAMP
Entry boot installation clamp tool
SCR.HAR
Hand scraper installation tool
Note: Installation involves the use of an electrofusion welder unit which requires
the use of a step up transformer.
190
1
XP ducting
2
XP pipe (secondary layer outside of sump)
3
XP pipe (primary layer exposed inside sump)
4
Fusion ducted entry boot
5
Reducing boot (included with fusion ducted entry boot)
6
Rigid split test boot
7
Polyethylene sump wall
7
4
6
3
5
1
2