UL Catalog 2024-2025 - Flipbook - Page 17
CORROSION CONTROL
ORDERING INFORMATION
Corrosion Control™ Advanced Protection Submersible Turbine Pumps Common Configurations
Model
Description
ISTAPMVS4-VL1
4 hp Corrosion Control™ AP variable speed with MagShell™
Model Length Range*
64"–92"
ISTAPMVS4-VL2
4 hp Corrosion Control™ AP variable speed with MagShell™
95"–156"
127"–218"
ISTAPMVS4-VL3
4 hp Corrosion Control™ AP variable speed with MagShell™
ISTAPM-1
2 hp Corrosion Control™ AP variable speed with MagShell™
59"–87"
ISTAPM-2
2 hp Corrosion Control™ AP variable speed with MagShell™
90"-151"
ISTAPM-3
2 hp Corrosion Control™ AP variable speed with MagShell™
122"-213"
STPAPM200-VL1
2 hp Corrosion Control™ AP fixed speed with MagShell™
63"-91"
STPAPM200-VL2
2 hp Corrosion Control™ AP fixed speed with MagShell™
94"-154"
126"–217"
STPAPM200-VL3
2 hp Corrosion Control™ AP fixed speed with MagShell™
STPAPHM200-VL1
2 hp Corrosion Control™ AP high pressure fixed speed with MagShell™
63"–92"
STPAPHM200-VL2
2 hp Corrosion Control™ AP high pressure fixed speed with MagShell™
94"–155"
126"–218"
STPAPHM200-VL3
2 hp Corrosion Control™ AP high pressure fixed speed with MagShell™
STPAP150-VL1
1½ hp Corrosion Control™ AP fixed speed
60"–88"
STPAP150-VL2
1½ hp Corrosion Control™ AP fixed speed
91"–152"
123"–214"
STPAP150-VL3
1½ hp Corrosion Control™ AP fixed speed
STPAPH150-VL1
1½ hp Corrosion Control™ AP high pressure fixed speed
61"–89"
STPAPH150-VL2
1½ hp Corrosion Control™ AP high pressure fixed speed
92"–152"
124"–215"
STPAPH150-VL3
1½ hp Corrosion Control™ AP high pressure fixed speed
STPAP75-VL1
3⁄4 hp Corrosion Control™ AP fixed speed
57"–86"
STPAP75-VL2
3⁄4 hp Corrosion Control™ AP fixed speed
88"–149"
STPAP75-VL3
3⁄4 hp Corrosion Control™ AP fixed speed
120"–212"
Notes:
1. Remove “M” from model number for non-MagShell™ pump motor assembly (where applicable).
2. STPAP/ISTAP models are listed for compatibility with fuel mixtures containing diesel fuel with up to 20% biodiesel, 100% biodiesel, up to 85% ethanol with gasoline, and
20% MTBE, 20% ETBE or 17% TAME with gasoline.
3. All models are supplied with a standard check valve unless factory option “R” or “W” is specified.
4. All above ISTAP models can only be powered by a MagVFC™. 4 hp models require three-phase incoming power supply,
2 hp models can be supplied with single- or three-phase incoming power.
5. All above STPAP models require single-phase, 208-230 VAC, 60 Hz incoming power.
6. 4" riser pipe, if supplied locally, must be 4½" OD by 3⁄16" WT tubing.
7. For riser pipe lengths 31" to 60", adder charge applies.
*Model length (A) defined as the dimension from the turbine manifold bottom to the pump motor inlet.
Factory Installed Options
Specified in model number at time of STP order.
Model
Description
F
Floating suction adapter, 1½" NPT female, must be factory installed
K
IFS (intake filter screen) factory assembled to pump motor assembly
R
Model R check valve, factory installed, for Veeder-Root™ PLLD Line Leak
Field Installed Options
Model
Description
5874202800
MagVFC™, 2 hp or 4 hp variable frequency controller, one required per IST
400137937
Syphon check valve
400818921
STP-CBS, single-phase control box with lockout switch, 110 Volt coil
402312931
STP-DHI + SPGC-220, combo DHI with factory wired SPGC-220 Guardian Series™ Single Phase Controller
402313921
STP-DHI-CBS, combo DHI with factory wired STP-CBS
402459931
Model 65 psi check valve (for secondary of manifolded STPs with Veeder-Root™ PLLD)
402507930
Secondary syphon kit (when two syphon primes are required for one STP)
5800100220
SPGC-220 Guardian Series™ Single Phase Controller, 220 Volt
5800300100
STP-DHI, dispenser hook isolation for 110 Volt dispenser handle switches, up to eight each
17