FFS-0772 Forecourt Guide No 6 InteractiveSpreads - Flipbook - Page 41
EVO™ SERIES CABLE: S P E C I F I C A T I O N S
BELDEN CABLE TO USE WITH EVO™ SERIES EQUIPMENT
Franklin Electric requires the use of cable with specifications listed below when
installing EVO™ Series components. It is required to follow the specifications below.
Please consult the cable manufacturer for specifications.
E V O ™ S E R I E S C O M P O N E N T S T H AT U S E S H I E L D E D T W I S T E D P A I R C A B L E
Probes (TSP-LL2 and FMP-LL3)
Line Leak Transducers (TS-LSU500)
Discriminating Magnetostrictive Sensor (TS-DMS)
C O M M O N C A B L E S P E C I F I C AT I O N S
Shielded Twisted Pair
Wire must be 22AWG or greater
Cable jacket must be oil/water resistant
FOR CABLE RUNS UP TO 500 FEET
Capacitance is rated less than 100 picofarad (pF) per foot
Inductance is rated less than 0.2 µH/ft.
Belden cable that meet these requirements:
• 87760, 87761
FOR CABLE RUNS UP TO 1,000 FEET
Capacitance is rated less than 60 pF per foot
Inductance is rated less than 0.2 µH/ft.
Belden cable that meet these requirements:
• 88760, 8760, 8770
FOR CABLE RUNS UP TO 1,500 FEET
Capacitance Conductor to Conductor is rated less than 20 pF per foot
Inductance is rated less than 0.3 µH/ft.
Belden cable that meet these requirements:
• 89182
41