FFS-0772 Forecourt Guide No 6 InteractiveSpreads - Flipbook - Page 27
TS-RK AND TS-RA1 TANK: O V E R F I L L
TS-RA2 TANK: O V E R F I L L
ALARM WIRING
ALARM WIRING
SW1 SWITCH POSITION SETTINGS:
SW1
O 1 2 3
N
SOUND
LEVEL
POS.
1
TONE
POS.
2
POS.
3
POS.
4
High dB*
ON*
Horn
(continuous)*
ON*
ON*
ON*
Bell
ON
OFF
ON
March Time
Horn
OFF
OFF
ON
OFF
4
110 VAC (LINE)
110 VAC (NEUT)
GND
N STB L
EXT ALARM CON.
Standard
db
N AUD L
OFF
TS-RA2
Code-3 Horn
OFF
ON
Code-3 Tone
OFF
ON
ON
Slow Whoop
OFF
ON
OFF
Siren
ON
OFF
OFF
HI/LO
OFF
OFF
OFF
* Factory default
TS-RA1
2AG 3A Fuse
2AG 3A Fuse
1-1 LINE
1-2 NEUTRAL
1-3 GROUND
To 110 VAC
Power Supply
1-2 NEUTRAL
1-3 GROUND
REMOTE ALARM SIGNAL
REMOTE ALARM SIGNAL
1-5
1-5
2-1
LATCH
MODE
ACKN
SWITCH
1-6 FLASH DRIVE
2-2
2-3
2-4
NC1
TS-RK
LATCH
MODE
1-8 OUTPUT
1-6 FLASH DRIVE
2-3
2-4
1-7 FLASH SHUNT
1-8 OUTPUT
1-9 OUTPUT RETURN
Console Relay Outputs
TS-RK
NC1
C1
C1
NO1
NO1
NC2
2-1
2-2
1-7 FLASH SHUNT
1-9 OUTPUT RETURN
Console Relay Outputs
To 110 VAC
Power Supply
1-4
1-4
ACKN
SWITCH
1-1 LINE
NC2
C2
C2
NO2
NO2
53