EN Catalog 2021-22 - Catalog - Page 256
ORDER INFORMATION
High Capacity Submersible Turbine Pump Model Designation System
A typical turbine model designation has up to five components to define
the pump being supplied as follows:
STP XXXXX Y - A - B
•
STP = Basic Model Designation
Note: Standard models up to 10% ethanol capable.
•
XXXXX = Factory Installed Options
•
HCP model designations may include one or more of the following
characters in alphabetical order: AG = Alcohol-gasoline compatible (85%
ethanol capable).
Note: Standard models 0% to 10% ethanol capable
•
•
F = Floating suction adapter (3" NPT male adapter)
*R = Model R check valve (1.65 bar relief/1.51 bar reset for PLLD)
*Note: If not otherwise specified, all HCP models supplied with standard
model check valve (2.76 bar relief/2.41 bar reset for MLD, TS-LS300 and
TS-LS500).
•
•
•
A
Y = Pump Motor Horsepower/Electrical Rating
•
•
3C = 3 Hp, 380-415 VAC, 50 Hz three phase
5C = 5 Hp, 380-415 VAC, 50 Hz three phase
A = Model Length
•
Model length is expressed as three numeric characters that indicate
the length of the HCP from the turbine manifold bottom to the pump
motor inlet in inches, available from 1524 mm to 5080 mm
(additional charge for models 3353 mm and longer).
B = Riser Pipe Length
•
For full diagram see previous page.
Riser pipe length is expressed as two numeric characters that
indicate the total length of the riser in inches. Riser pipes are
available from 152mm to 1524 mm in 76 mm increments (additional
charge and lead time for risers 686 mm or longer).
High Capacity Turbine Pumps
(available as fixed length models only)**
Model
Description
STP3C*
6" STP three phase, 380-415 VAC, 50 Hz
STP5C*
6" STP three phase, 380-415 VAC, 50 Hz
Factory Installed Options
Model
Description
401227001
Floating suction adapter, 3" male NPT (must be ordered
with STP)
R
Model R relief valve factory installed, for Veeder Root (*)
PLLD
*Please call customer service for lead time on this item.
1. STP models are listed for compatibility with fuel mixtures containing up to
10% ethanol with gasoline, up to 5% biodiesel with diesel fuels, 20% MTBE,
20% ETBE, or 17% TAME with gasoline.
2. All models are supplied with a standard check valve unless factory option "R"
is specified.
3. All above models require 380-415 VAC, three-phase, 50 Hz incoming power.
Field Installed Options
Model
Description
401165930
Syphon system
STP-CBB3C
3 hp, 380-415 VAC, 50 Hz, three-phase motor starter,
240 VAC coil
STP-CBB5C
5 hp, 380-415 VAC, 50 Hz, three-phase motor starter,
240 VAC coil
STP-SCIIIC
Three-phase 380-415 VAC smart controller
4. 6" riser pipe, if supplied locally, must be 6" OD by 1/4" WT tubing.
5. For riser pipe lengths 686 mm to 1524 mm, additional charge applies. Call
Customer Services for lead times.
** Model length (A) defined as the dimension from turbine manifold bottom to
pump motor inlet. Model length (A) can be a minimum of 1524 mm to a
maximum of 5080 mm. Adder (p/n 401190911) applies if model length (A) is
3353 mm to 4318 mm or adder (p/n 401190914) applies if model length (A) is
4319 mm to 5080 mm (charges are for additional packaging STP). Call
Customer Services for lead times.
6" STP Extractable
Less manifold, riser and PMA.
Model
Description
HCPEXT-XXX
6" fixed length extractable (XXX indicates model length,
minimum 1524 mm and maximum 5080 mm)***
*** Fixed Length adders apply for extractable model lengths 3353 mm to
5080 mm. Call Customer Services for lead times.
256
B
** STP-SCIIIC is compatible with FE PETRO® 3 and 5 Hp submersibles and
competitive makes, input voltage rated 380-415 VAC three phase