EN Catalog 2021-22 - Catalog - Page 238
ORDERING INFORMATION CONTINUED
Corrosion Control™ Advanced Protection Submersible Turbine Pumps Common Configurations
Model
Description
Model Length Range Number
Model Length* Range
ISTAPVS4-VL1
4 hp AP variable speed
VL1
1613 mm– 2355 mm
ISTAPVS4-VL2
4 hp AP variable speed
VL2
2401 mm–3962 mm
ISTAPVS4-VL3
4 hp AP variable speed
VL3
3214 mm–5556 mm
ISTAP-1
2 hp AP variable speed
VL1
1486 mm–2228 mm
ISTAP-2
2 hp AP variable speed
VL2
2274 mm–3835 mm
ISTAP-3
2 hp AP variable speed
VL3
3087 mm–5429 mm
STPAP200B-VL1
2 hp AP fixed speed, single phase
VL1
1632 mm–2374 mm
STPAP200B-VL2
2 hp AP fixed speed, single phase
VL2
2420 mm–3981 mm
STPAP200B-VL3
2 hp AP fixed speed, single phase
VL3
3233 mm–5575 mm
STPAP200C-VL1
2 hp AP fixed speed, three phase
VL1
1575 mm–2317 mm
STPAP200C-VL2
2 hp AP fixed speed, three phase
VL2
2363 mm–3924 mm
STPAP200C-VL3
2 hp AP fixed speed, three phase
VL3
3175 mm–5518 mm
STPAP150B-VL1
1-1/2 hp AP fixed speed, single phase
VL1
1556 mm–2298 mm
STPAP150B-VL2
1-1/2 hp AP fixed speed, single phase
VL2
2344 mm–3905 mm
STPAP150B-VL3
1-1/2 hp AP fixed speed, single phase
VL3
3156 mm–5499 mm
STPAP150C-VL1
1-1/2 hp AP fixed speed, three phase
VL1
1531 mm –2273 mm
STPAP150C-VL2
1-1/2 hp AP fixed speed, three phase
VL2
2318 mm–3879 mm
STPAP150C-VL3
1-1/2 hp AP fixed speed, three phase
VL3
3131 mm–5473 mm
STPAP75B-VL1
3/4 hp AP fixed speed, single phase
VL1
1499 mm –2241 mm
STPAP75B-VL2
3/4 hp AP fixed speed, single phase
VL2
2286 mm–3848 mm
STPAP75B-VL3
3/4 hp AP fixed speed, single phase
VL3
3099 mm–5441 mm
STPAP75C-VL1
3/4 hp AP fixed speed, three phase
VL1
1480 mm–2222 mm
STPAP75C-VL2
3/4 hp AP fixed speed, three phase
VL2
2267 mm–3829 mm
STPAP75C-VL3
3/4 hp AP fixed speed, three phase
VL3
3080 mm–5422 mm
Notes:
1. STPAP/ISTAP models are listed for compatibility with fuel mixtures
containing diesel fuel with up to 20% biodiesel, 100%biodiesel, up to 85%
ethanol with gasoline, and 20% MTBE, 20% ETBE or 17% TAME with
gasoline.
4. All above STPAP single phase models (75B, 150B, 200B) require
single-phase, 200–250 VAC, 50 Hz incoming power. All above STPAP three
phase models (75C, 150C, 200C) require three-phase, 380-415 VAC, 50 Hz
incoming power.
2. All models are supplied with a standard check valve unless factory option
"R" or "W" is specified.
5. 4" riser pipe, if supplied locally, must be 4½" OD by 3/16" WT tubing.
6. For riser pipe lengths 787 mm to 1524 mm, adder charge applies (call
customer service for lead times).
3. All above ISTAPVS4 4 hp models can only be powered by an EcoVFC™ with
three-phase incoming power supply. All above ISTAP2 hp models can be
powered by a MagVFC™ with single-phase incoming power or an EcoVFC™
with three-phase incoming power.
Factory Installed Approvals
May specify one in model number at time of order.
*Model length (A) defined as the dimension from the turbine manifold bottom to
the pump motor inlet.
Factory Installed Options
Specified in model number at time of STP order.
Model Description
Model
Description
(ATXF)
STP with ATEX flameproof approval for EN markets
(RT)
STP with ROSTEST approval for Eastern European markets
Note: If not otherwise specified, all models are supplied to UL approval as
standard. Consult factory for other local approvals.
F
Floating suction adapter, 1½" NPT female, must be factory installed
K
IFS (intake filter screen) factory assembled to pump motor assembly
R
Model R check valve, factory installed, for Veeder-Root™ PLLD Line Leak
W
Model W check valve, factory installed, for Red Jacket PPM4000 Line Leak
Field Installed Options
238
Model
Description
5874202800
MagVFC™, 2 hp or 4 hp variable frequency controller, one required per IST
400137908
Syphon check valve (when ordered with STP)
400818921
STP-CBS, single-phase control box with lockout switch, 110 Volt coil
402312931
STP-DHI + SPGC-220, combo DHI with factory wired SPGC-220 Guardian Series™ Single Phase Controller
402313921
STP-DHI-CBS, combo DHI with factory wired STP-CBS
402459931
Model 65 psi check valve (for secondary of manifolded STPs with Veeder-Root™ PLLD)
402507930
Secondary syphon kit (when two syphon primes are required for one STP)
5800100220
SPGC-220 Guardian Series™ Single Phase Controller, 220 Volt
5800300100
STP-DHI, dispenser hook isolation for 110 Volt dispenser handle switches, up to eight each