PRODUCT GUDE interactive 2024 - Flipbook - Page 85
INSULATION FIXINGS
2002/95/C
SETTING INSTRUCTIONS
For Insulation Anchors
DRYWALL
SCREWS
WOODMASTER®
RANGE
ACCESSORIES
SUPPLEMENTARY
INFORMATION
1. Set drill hole
2. Clean out drill hole from the base
3. Knock insulation fastener through the insulation panel
with a hammer
4. Anchor disc must fully contact the insulation panel
MASONRY SCREWS
& ANCHORS
NOMINAL DIAMETER OF MINIMUM DEPTH FOR PILOT HOLES [GIA and A2GIA Ranges]
FACTOR
SYMBOL
UNIT
VARIABLE
Nominal diameter of fasteners
dnom
mm
8.0
Compressive strength of concrete
substrate
fck.cube
MPa
≥ C20 ≤ C80
[NOTE 1]
[NOTES 4 & 5]
FOR PILOT HOLES FOR EACH VARIABLE
hnom
mm
35.0
40.0
45.0
Nominal diameter of pilot hole drill bit
hdrill,nom
mm
8.0
8.0
8.0
Minimum depth of drilled hole
hdrill,min
mm
45.0
50.0
55.0
E昀昀ec琀椀ve embedment depth
[NOTE 2]
INSULATION
FIXINGS
AND MINIMUM DEPTHS
BI-METAL TEK®
RANGE
[NOTE 3]
NOMINAL DIAMETER
STRESS PLATES/
WASHERS
VARIABLES AFFECTING NOMINAL DIAMETER AND MINIMUM DEPTH OF PILOT HOLES
NOTES
CARBON STEEL TEK®
RANGE
1. Compressive strength pursuant to BS EN 206-1: 2000,
2. E昀昀ec琀椀ve embedment depth is the minimum amount of expansion sleeve engaged in the substrate for a given applica琀椀on,
3. Only Evolu琀椀on PGM approved drill bits are permissible for use due to manufacturing tolerances,
®
®
4. Installers must ensure adequate perpendicularity of the pilot hole (not more than ± 5° incidence from the normal),
5. Installers must ensure adequate control of the pilot hole depth (hdrill,min ≥ – 1.0mm ≤ + 5.0mm).
85